Natural ventilation, low CO 2 and air filtration are associated with reduced indoor air respiratory pathogens
Preprint
Abstract
Summary: Currently, the real-life impact of indoor climate, human behavior, ventilation and air filtration on respiratory pathogen detection and concentration are poorly understood. This hinders the interpretability of bioaerosol quantification in indoor air to surveil respiratory pathogens and transmission risk. We tested 341 indoor air samples from 21 community settings for 29 respiratory pathogens using qPCR. On average, 3.9 pathogens were positive per sample and 85.3% of samples tested positive for at least one. The number of detected pathogens and their respective concentrations varied significantly by pathogen, month, and age group in generalized linear (mixed) models and generalized estimating equations. High CO 2 and low natural ventilation were independent risk factors for detection. CO 2 concentration and air filtration were independently associated with their concentration. Occupancy, sampling time, mask wearing, vocalization, temperature, humidity and mechanical ventilation were not significant. Our results support the importance of ventilation and air filtration to reduce transmission.Keywords
This publication has 27 references indexed in Scilit:
- Extensive Viable Middle East Respiratory Syndrome (MERS) Coronavirus Contamination in Air and Surrounding Environment in MERS Isolation WardsClinical Infectious Diseases, 2016
- Association of classroom ventilation with reduced illness absence: a prospective study in California elementary schoolsIndoor Air, 2013
- In China, Students in Crowded Dormitories with a Low Ventilation Rate Have More Common Colds: Evidence for Airborne TransmissionPLOS ONE, 2011
- The impact of portable high-efficiency particulate air filters on the incidence of invasive aspergillosis in a large acute tertiary-care hospitalAmerican Journal of Infection Control, 2010
- Reduction in MRSA environmental contamination with a portable HEPA-filtration unitJournal of Hospital Infection, 2006
- Neonatal erythropoiesis and subsequent anemia in HIV-positive and HIV-negative Zimbabwean babies during the first year of life: a longitudinal studyBMC Infectious Diseases, 2006
- The National Human Activity Pattern Survey (NHAPS): a resource for assessing exposure to environmental pollutantsJournal of Exposure Science & Environmental Epidemiology, 2001
- Hospital Ventilation and Risk for Tuberculous Infection in Canadian Health Care WorkersAnnals of Internal Medicine, 2000
- Investigation of the Concentration of Bacteria and Their Cell Envelope Components in Indoor Air in Two Elementary SchoolsJournal of the Air & Waste Management Association, 2000
- Tuberculosis Outbreak in a General Hospital: Evidence for Airborne Spread of InfectionAnnals of Internal Medicine, 1972