The Rapid Test Based on Leishmania infantum Chimeric rK28 Protein Improves the Diagnosis of Canine Visceral Leishmaniasis by Reducing the Detection of False-Positive Dogs
Open Access
- 5 January 2016
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS Neglected Tropical Diseases
- Vol. 10 (1) , e0004333
Abstract
Visceral Leishmaniasis (VL) has spread to many urban centers worldwide. Dogs are considered the main reservoir of VL, because canine cases often precede the occurrence of human cases. Detection and euthanasia of serologically positive dogs is one of the primary VL control measures utilized in some countries, including Brazil. Using accurate diagnostic tests can minimize one undesirable consequence of this measure, culling false-positive dogs, and reduce the maintenance of false-negative dogs in endemic areas. In December 2011, the Brazilian Ministry of Health replaced the ELISA (EIE CVL) screening method and Indirect Immunofluorescence Test (IFI CVL) confirmatory method with a new protocol using the rapid DPP CVL screening test and EIE CVL confirmatory test. A study of diagnostic accuracy of these two protocols was done by comparing their performance using serum samples collected from a random sample of 780 dogs in an endemic area of VL. All samples were evaluated by culture and real time PCR; 766 out of the 780 dogs were tested using the previous protocol (IFI CVL + EIE CVL) and all 780 were tested using the current protocol (DPP CVL + EIE CVL). Performances of both diagnostic protocols were evaluated using a latent class variable as the gold standard. The current protocol had a higher specificity (0.98 vs. 0.95) and PPV (0.83 vs. 0.70) than the previous protocol, although sensitivity of these two protocols was similar (0.73). When tested using sera from asymptomatic animals, the current protocol had a much higher PPV (0.63 vs. 0.40) than the previous protocol (although the sensitivity of either protocol was the same, 0.71). Considering a range of theoretical CVL prevalences, the projected PPVs were higher for the current protocol than for the previous protocol for each theoretical prevalence value. The findings presented herein show that the current protocol performed better than previous protocol primarily by reducing false-positive results. Visceral Leishmaniasis (VL) is a major public health problem. Its control is based on detection and culling of positive dogs, treatment of human cases and vector control. Canine cases often precede the occurrence of human cases; hence, disease control in dogs is important. Use of accurate diagnostic tests is required to avoid culling false-positive dogs and to minimize the number of false-negative dogs that are maintained in endemic areas. In December 2011, the Brazilian Ministry of Health changed the diagnostic protocol for canine VL (CVL). In the present study, the accuracy of this current protocol was compared to the previous one using serum samples of 780 dogs from an endemic area of VL. The findings revealed that the current protocol performed better than the previous protocol primarily by reducing false-positive results. Considering different theoretical prevalence values, the current protocol misdiagnosed fewer dogs than the previous one.Keywords
This publication has 33 references indexed in Scilit:
- Evaluation of a Rapid Device for Serological Diagnosis of Leishmania infantum Infection in Dogs as an Alternative to Immunofluorescence Assay and Western BlottingClinical and Vaccine Immunology, 2013
- Accuracy of real-time PCR, Gram stain and culture for Streptococcus pneumoniae, Neisseria meningitidis and Haemophilus influenzae meningitis diagnosisBMC Infectious Diseases, 2013
- Estimating the True Accuracy of Diagnostic Tests for Dengue Infection Using Bayesian Latent Class ModelsPLOS ONE, 2013
- Validation of a New Test for Schistosoma haematobium Based on Detection of Dra1 DNA Fragments in Urine: Evaluation through Latent Class AnalysisPLOS Neglected Tropical Diseases, 2012
- Evaluation of a novel chromatographic immunoassay based on Dual-Path Platform technology (DPP® CVL rapid test) for the serodiagnosis of canine visceral leishmaniasisTransactions of the Royal Society of Tropical Medicine and Hygiene, 2012
- Evaluation of Two rK39 Dipstick Tests, Direct Agglutination Test, and Indirect Fluorescent Antibody Test for Diagnosis of Visceral Leishmaniasis in a New Epidemic Site in Highland EthiopiaThe American Journal of Tropical Medicine and Hygiene, 2011
- Leishmania Infection: Laboratory Diagnosing in the Absence of a “Gold Standard”The American Journal of Tropical Medicine and Hygiene, 2010
- Development of Recombinant Chimeric Antigen Expressing Immunodominant B Epitopes ofLeishmania infantumfor Serodiagnosis of Visceral LeishmaniasisClinical and Vaccine Immunology, 2005
- Development of a Dipstick Assay for Detection of Leishmania -Specific Canine AntibodiesJournal of Clinical Microbiology, 2004
- The value of latent class analysis in medical diagnosisStatistics in Medicine, 1986