Hybrid non scan with built-in self-test for fault coverage improvement
Open Access
- 1 January 2023
- conference paper
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2795 (1)
Abstract
Conventional design for testability (DFT) method that implements scan designs requires long test application time and costly automatic test equipment (ATE). On the other hand, built-in self-test (BIST) methods reduce the test time, but with low fault coverage. In this paper, we propose a DFT method that combines two DFT methods which is BIST and a non scan method in order to improve the fault coverage at register transfer level (RTL). BIST architecture with a standard linear feedback shift register (LFSR) is implemented as the test pattern generator. Non scan method is implemented to tackle the problem of poor testability at the internal circuit. R-graph that represents the connection of the circuit is used to derive the circuit at RTL. The self-loop register from the generated R-graph is selected so that the thru function is added to the self-loop in order to improve the testability of the circuit. The performance of the proposed DFT method will be measured on several circuits to show the effectiveness of the proposed DFT method using Synopsys tool. It will be compared to a stand-alone BIST method in terms of fault coverage. Stuck-at fault is considered as fault modeling using Tetramax tool. The results show that the proposed DFT method achieves higher fault coverage compared to the stand-alone BIST method.Keywords
This publication has 13 references indexed in Scilit:
- Logic BIST With Capture-Per-Clock Hybrid Test PointsIEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, 2018
- An efficient controlled LFSR hybrid BIST schemeIEICE Electronics Express, 2018
- Full-scan LBIST with capture-per-cycle hybrid test points2017
- Hybrid BIST optimization using reseeding and test set compactionMicroprocessors and Microsystems, 2008
- A New Scan Design Technique Based on Pre-Synthesis Thru Functions2006
- New Non-Scan DFT Techniques to Achieve 100% Fault EfficiencyJournal of Electronic Testing, 2004
- A hybrid BIST architecture and its optimization for SoC testing2003
- BIST-based test and diagnosis of FPGA logic blocksIEEE Transactions on Very Large Scale Integration (VLSI) Systems, 2001
- A non-scan DFT method at register-transfer level to achieve complete fault efficiency2000
- First results of ITC'99 benchmark circuitsIEEE Design & Test of Computers, 2000