Evaluation of Spectral Estimation Parameters for Direct Sampling FFT-Based Measuring Receivers
Open Access
- 16 April 2024
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Signal Processing
- Vol. 5, 588-598
Abstract
The standard CISPR 16-1-1 defines the measuring receiver using a black-box approach and sets requirements for its accuracy and spectral properties. Traditionally, such test receivers were developed using a superheterodyne architecture. Recently, time-domain electromagnetic emission measurement systems have been built employing direct sampling instruments, mainly oscilloscopes, and relying on specific signal processing to emulate the performance of compliant instruments. In these cases, the short-time Fourier transform is used for spectral estimation, but the corresponding electromagnetic compatibility standards lack details for its correct use with respect to parameters such as windowing function, overlapping factor, and frequency interpolation. Moreover, it is unclear which combination of spectral estimation parameters is best fit for this purpose. Obtaining reliable, consistent and low uncertainty spectral estimates of electromagnetic emissions measured in time-domain needs appropriate configuration and tuning of the signal processing algorithms. This paper investigates the error in the calculated spectrum for various reference signals: multitone, chirp pulses and rectangular pulses. The analysis is carried out for each CISPR band from A to D, that is, between 9 kHz and 1 GHz. After $489.6\times 10^{3}$ iterations, distributed in 1700 different digital implementations of the CISPR 16-1-1 measuring receiver, the simulations outcomes point to certain sets of parameters that showed satisfactory performance overall, being the Nutall, Kaiser, and Parzen windows with more than 75% of overlapping and using interpolation factor higher than 5, generally suitable. Calibration results are used to experimentally verify that a valid set of parameters is adequate to fulfil CISPR 16-1-1 requirements.Keywords
This publication has 26 references indexed in Scilit:
- Metrological Characterization of EMI Receivers2023
- On the suitability of the CISPR 16 method for measuring conducted emissions in the 2–150kHz range in low voltage gridsElectric Power Systems Research, 2022
- Time-domain Multitone Impedance Measurement System for Space Applications2022
- Impact of short-time fourier transform parameters on the accuracy of EMI spectra estimates in the 2-150 kHz supraharmonic intervalElectric Power Systems Research, 2021
- Full Time Domain EMI Measurement System Applied to Railway Emissions According to IEC 62236-3-1/EN 50121-3-1 Standards2018
- Digital Signal Processing and Spectral Analysis for Scientists2016
- Improving time-domain EMI measurements through digital signal processingIEEE Electromagnetic Compatibility Magazine, 2015
- Technical analysis of ISO/DIS 17025-general requirements for the competence of testing and calibration laboratories2003
- Signal processing methods for time domain EMI measurements2003
- Smoothing Periodograms from Time-Series with Continuous SpectraNature, 1948