FibroTest/Fibrosure for Significant Liver Fibrosis and Cirrhosis in Chronic Hepatitis B: A Meta-Analysis
- 1 June 2014
- journal article
- review article
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 109 (6) , 796-809
Abstract
Extent of liver fibrosis is one of the most important factors in determining prognosis and the need for active treatment in chronic hepatitis B (CHB). Noninvasive alternatives such as FibroTest/Fibrosure (FT) have been developed in order to overcome the shortcomings of liver biopsy (LB). We aimed to systematically review studies describing the diagnostic accuracy of FT for predicting CHB-related fibrosis. MEDLINE and EMBASE searches and hand searching methods were performed to identify studies that assessed the diagnostic accuracy of FibroTest in HB patients using LB as a reference standard. We used a hierarchical summary receiver operating curves model and the bivariate model to produce summary receiver operating characteristic curves and pooled estimates of sensitivity and specificity. We included 16 studies (N=2494) and 13 studies (N=1754) in the heterogenous meta-analysis for liver fibrosis and cirrhosis, respectively. The area under the hierarchical summary receiver operating curve for significant liver fibrosis and for all included studies was 0.84 (95% confidence interval (CI): 0.78-0.88). At the FT threshold of 0.48, the sensitivity, specificity, and diagnostic odds ratio (DOR) of FT for significant fibrosis were 61 (48-72%), 80 (72-86%), and 6.2% (3.3-11.9), respectively. The area under the hierarchical summary receiver operating curve for liver cirrhosis and for all included studies was 0.87 (95% CI: 0.85-0.90). At the FT threshold of 0.74, the sensitivity, specificity, and DOR of FT for cirrhosis were 62 (47-75%), 91 (88-93%), and 15.7% (8.6-28.8), respectively. FibroTest is of value in exclusion of patients with CHB-related cirrhosis, but has suboptimal accuracy in the detection of significant fibrosis and cirrhosis. It is necessary to further improve the test or combine it with other noninvasive modalities in order to improve accuracy.Keywords
This publication has 58 references indexed in Scilit:
- Prospective Validation of FibroTest in Comparison with Liver Stiffness for Predicting Liver Fibrosis in Asian Subjects with Chronic Hepatitis BPLOS ONE, 2012
- Performance of Biomarkers FibroTest, ActiTest, SteatoTest, and NashTest in Patients with Severe Obesity: Meta Analysis of Individual Patient DataPLOS ONE, 2012
- Liver Stiffness Measurement and Biochemical Markers in Senegalese Chronic Hepatitis B Patients with Normal ALT and High Viral LoadPLOS ONE, 2011
- Noninvasive Markers of Hepatic Fibrosis in Chronic Hepatitis BCurrent Hepatitis Reports, 2011
- Diagnostic accuracy of FibroScan and comparison to liver fibrosis biomarkers in chronic viral hepatitis: A multicenter prospective study (the FIBROSTIC study)Journal of Hepatology, 2010
- Reduced Mortality Rates Following Elective Percutaneous Liver BiopsiesGastroenterology, 2010
- Comparison of ELF, FibroTest and FibroScan for the non-invasive assessment of liver fibrosisBMC Gastroenterology, 2010
- Exceeding the limits of liver histology markersJournal of Hepatology, 2009
- Meta-analyses of FibroTest diagnostic value in chronic liver diseaseBMC Gastroenterology, 2007
- Sampling Variability of Liver Fibrosis in Chronic Hepatitis CHepatology, 2003