Abstract
The increased inertia of very high-energy electrons (VHEEs) due to relativistic effects reduces scattering and enables irradiation of deep-seated tumours. However, entrance and exit doses are high for collimated or diverging beams. Here, we perform a study based on Monte Carlo simulations of focused VHEE beams in a water phantom, showing that dose can be concentrated into a small, well-defined volumetric element, which can be shaped or scanned to treat deep-seated tumours. The dose to surrounding tissue is distributed over a larger volume, which reduces peak surface and exit doses for a single beam by more than one order of magnitude compared with a collimated beam.
Funding Information
  • RCUK | Engineering and Physical Sciences Research Council (EP/J018171/1, EP/J500094/1, EP/N028694/1, EP/J018171/1, EP/J500094/1, EP/N028694/1, EP/J018171/1, EP/J500094/1, EP/N028694/1, EP/J018171/1, EP/J500094/1, EP/N028694/1, EP/J018171/1, EP/J500094/1, EP/N028694/1, EP/J018171/1, EP/J500094/1, EP/N028694/1)
  • EC | Horizon 2020 (654148, 654148, 312453, 653782)
  • Extreme Light Infrastructure (ELI) European Project

This publication has 34 references indexed in Scilit: