Comparison of image quality in magnetic resonance imaging of the knee at 1.5 and 3.0 Tesla using 32-channel receiver coils
- 8 May 2008
- journal article
- research article
- Published by Springer Nature in European Radiology
- Vol. 18 (10) , 2258-2264
Abstract
We examined to what degree the visualization of anatomic structures in the human knee is improved using 3.0-T magnetic resonance imaging (MRI) and many element RF receive coils as compared to 1.5 T. We imaged 20 knees at 1.5 and 3.0 T using T2-weighted STIR, T2-weighted gradient echo, T1-weighted spin-echo, true-FISP and T2-weighted fast spin echo techniques in conjunction with 32-element RF coil arrays. The 3.0-T examination was considerably faster than its 1.5-T counterpart. A superior subjective visibility at 3.0 T vs 1.5 T was found in 27 of 50 evaluated structures (meniscus, ligaments) with the exception of true-FISP techniques. The 3.0-T examination provided a better visibility (evaluated by blinded consensus-reading by two radiologists) of small structures such as the ligamentum transversum genu. Also, cartilage was better delineated at 3.0 T. A 23% increased average signal-to-noise ratio as assessed using a temporal filter was observed at 3.0 T as compared to 1.5 T. At 3.0 T, imaging of the human knee is faster and results in a subjective visibility of anatomic structures that is superior to and competitive with 1.5 T.Keywords
This publication has 19 references indexed in Scilit:
- Sensitivity of Routine 1.0‐Tesla Magnetic Resonance Imaging Versus Arthroscopy as Gold Standard in Fresh Traumatic Chondral Lesions of the Knee in Young AdultsArthroscopy, 2006
- Ultra–High-Field MRI of Knee Joint at 7.0T: Preliminary ExperienceAcademic Radiology, 2006
- Image reconstruction in SNR units: A general method for SNR measurement†Magnetic Resonance in Medicine, 2005
- Accuracy and precision of quantitative assessment of cartilage morphology by magnetic resonance imaging at 3.0TArthritis & Rheumatism, 2005
- MR imaging of articular cartilage at 1.5 T and 3.0 T: Comparison of SPGR and SSFP sequencesOsteoarthritis and Cartilage, 2005
- Simultaneous perfusion and BOLD imaging using reverse spiral scanning at 3T: Characterization of functional contrast and susceptibility artifactsMagnetic Resonance in Medicine, 2002
- High-resolution MR imaging of the knee at 3 TActa Radiologica, 2000
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Quantification and improvement of the signal-to-noise ratio in a magnetic resonance image acquisition procedureMagnetic Resonance Imaging, 1996
- Signal-to-noise measures for magnetic resonance imagersMagnetic Resonance Imaging, 1993