Pulsed Excitation Source Multiplexed Fluorometry for the Simultaneous Measurement of Multiple Analytes. Continuous Measurement of Atmospheric Hydrogen Peroxide and Methyl Hydroperoxide
- 29 January 2003
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (5) , 1203-1210
Abstract
Presently, solid-state sources such as light-emitting diodes (LEDs) provide for intense, nearly monochromatic light. They are available over a broad range of emission wavelengths. Unlike incandescent and discharge lamps, LEDs can be turned on and off at high speeds. The resulting light pulses are highly reproducible. This allows the use of a single photomultiplier tube (PMT), often the most expensive component in a high-sensitivity measurement system, as a multiplexed detector with multiple, fiber-optic-coupled, fluorescence-detection cells excited by solid-state sources. A time resolution of 1 min is adequate in many continuous detection schemes. This enables multiple-channel single-detector multiplexed measurement without any loss of S/N. On the basis of this principle, we describe a new automated continuous instrument for the simultaneous measurement of atmospheric hydrogen peroxide and methyl hydroperoxide (MHP). A Nafion membrane diffusion scrubber (DS) is used with hematin-catalyzed oxidation of thiamine to thiochrome for the measurement of H2O2, and an expanded poly(tetrafluoroethylene) (ePTFE) DS is used with a H2O2 destruction catalyst and horseradish peroxidase-catalyzed oxidation of thiamine to thiochrome for the measurement of MHP. The respective limits of detection are 25 pptv and 15 pptv. Design, performance details, and illustrative results from a field campaign (Philadelphia NEO3PS study, 2001) are presented.Keywords
This publication has 27 references indexed in Scilit:
- Performance of an ultraviolet light-emitting diode-induced fluorescence detector in capillary electrophoresisElectrophoresis, 2002
- Shipboard determination of hydrogen peroxide in the western Mediterranean sea using flow injection with chemiluminescence detectionAnalytica Chimica Acta, 1998
- Blue light-emitting-diode-pumped point temperature sensor based on a fluorescence intensity ratio in Pr3+: ZBLAN glassOptical Review, 1997
- A solid-state instrument for fluorescence chemical sensors using a blue light-emitting diode of high intensityMeasurement Science and Technology, 1995
- Comparison of collection devices for atmospheric peroxidesEnvironmental Science & Technology, 1993
- A high-performance liquid chromatography system with an immobilized enzyme reactor for detection of hydrophilic organic peroxidesAnalytical Chemistry, 1991
- Determination of hydrogen peroxide by photoinduced fluorogenic reactionsAnalytica Chimica Acta, 1991
- Detection of methyl, hydroxymethyl and hydroxyethyl hydroperoxides in air and precipitationNature, 1989
- Determination of hydrogen peroxide with N,N-diethylaniline and 4-aminoantipyrine by use of an anion-exchange resin modified with manganese-tetrakis(sulphophenyl)porphine, as a substitute for peroxidaseTalanta, 1987
- Thermodynamics of the hydrogen peroxide-water systemEnvironmental Science & Technology, 1985