Sources of Variability in Measurements of Cardiac Troponin T in a Community-Based Sample: The Atherosclerosis Risk in Communities Study
- 1 June 2011
- journal article
- Published by Oxford University Press (OUP) in Clinical Chemistry
- Vol. 57 (6) , 891-897
Abstract
BACKGROUND: Application of cardiac troponin T (cTnT) as a marker of myocyte damage requires knowledge of its measurement variability. Using a highly sensitive assay for measurement, we evaluated the long-term storage stability of plasma cTnT at −70 °C and the sources of cTnT variability. METHODS: Samples from the Atherosclerosis Risk in Communities study collected in 1996–1998 and 2005–2006 were assayed centrally to quantify variability in cTnT attributable to processing (replicates from same blood draw, n = 87), laboratory (replicates after freeze thaw, n = 29), short-term (n = 40) and long-term biological variation (repeat visit, n = 38), and degradation in frozen storage (n = 7677). RESULTS: Approximately 30% of this population-based cohort had cTnT concentrations below the detection limit (3 ng/L). Reliability coefficients for all paired comparisons exceeded 0.93 except for samples drawn 8 years apart (r = 0.36). Sources of cTnT variation (as CVs) were: laboratory, 2.1% and 11.2% in those with and without heart failure, respectively; processing, 18.3%; biological, 16.6% at 6 weeks and 48.4% at 8 years. The reference change value at 6 weeks (68.5%) indicated that 4 samples are needed to determine a homeostatic set point within ±25%. The estimated cTnT degradation rate over the first year in long-term frozen storage was 0.36 ng/L per year. CONCLUSIONS: cTnT was detectable in approximately 70% of community-dwelling middle-aged study participants and stable in −70 °C storage. The variability in cTnT attributable to 1 freeze–thaw cycle is of small magnitude. The observed high laboratory and intraindividual (biological) reliability of cTnT support its use for population-based research, and in clinical settings that rely on classification and serial measurements.Keywords
Funding Information
- National Heart, Lung, and Blood Institute (N01-HC-55015, N01-HC-55016, N01-HC-55018, N01-HC-55019, N01-HC-55020, N01-HC-55021, N01-HC-55022)
This publication has 22 references indexed in Scilit:
- Biological and Analytical Variability of a Novel High-Sensitivity Cardiac Troponin T AssayClinical Chemistry, 2010
- Sensitive Troponin I Assay in Early Diagnosis of Acute Myocardial InfarctionNew England Journal of Medicine, 2009
- Atherosclerosis Risk in Communities (ARIC) Carotid MRI Flow Cytometry Study of Monocyte and Platelet Markers: Intraindividual Variability and ReliabilityClinical Chemistry, 2008
- Prognostic Value of Very Low Plasma Concentrations of Troponin T in Patients With Stable Chronic Heart FailureCirculation, 2007
- Future Biomarkers for Detection of Ischemia and Risk Stratification in Acute Coronary SyndromeClinical Chemistry, 2005
- Prognostic Value of Combination of Cardiac Troponin T and B-Type Natriuretic Peptide after Initiation of Treatment in Patients with Chronic Heart FailureClinical Chemistry, 2003
- Cardiac Troponin I Is Associated With Impaired Hemodynamics, Progressive Left Ventricular Dysfunction, and Increased Mortality Rates in Advanced Heart FailureCirculation, 2003
- Troponin T Levels in Patients with Acute Coronary Syndromes, with or without Renal DysfunctionNew England Journal of Medicine, 2002
- Generation and Application of Data on Biological Variation in Clinical ChemistryCritical Reviews in Clinical Laboratory Sciences, 1989
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986