What happens if you delay scanning Digora phosphor storage plates (PSPs) for up to 4 hours?
Authors:
- Ej WhaitesEWEj Whaites
- Gmb AmbrosanoGAGmb Ambrosano
- F Haiter NetoFNF Haiter Neto
- 1 May 2006
- journal article
- Published by Oxford University Press (OUP) in Dentomaxillofacial Radiology
- Vol. 35 (3) , 143-146
Abstract
To assess, both objectively and subjectively, the effects of different combinations of storage conditions and delaying scanning for up to 4 h on digital images captured using Digora phosphor storage plates (PSPs). Standardized images were obtained of an aluminium step wedge and dry mandible in acrylic using GE 1000 and phosphor storage plates (PSPs) from the Digora (Soredex) digital system. 12 plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored using three different storage combinations--(A) ambient temperature, (R) refrigeration and (S) low humidity, and then scanned after 10 min, 30 min, 1 h, 2 h, 3 h or 4 h. The objective analysis was carried out by pixel density measurements and the data analysed statistically using analysis of variance. Subjective analysis was carried out by three oral radiologists and the results analysed using the Mann Whitney U-test. Objective analysis showed loss of pixel density after 4 h using all storage combinations. Subjectively, this loss of density was not evident. There is a loss of image density at 4 h when using Digora PSPs which can not be detected clinically, but could compromise multisite research.Keywords
This publication has 9 references indexed in Scilit:
- Analysis of digital images acquired using different phosphor storage plates (PSPs) subjected to varying reading times and storage conditionsDentomaxillofacial Radiology, 2003
- Accuracy of caries detection with four storage phosphor systems and E-speed radiographsDentomaxillofacial Radiology, 2002
- A comparison of digital and film radiography in Dutch dental practices assessed by questionnaire.Dentomaxillofacial Radiology, 2002
- Estudo comparativo dos métodos de estimativa da idade óssea de Greulich & Pyle e Tanner & WhitehousePesquisa Odontológica Brasileira, 2000
- PRINCIPLES OF DIGITAL IMAGINGDental Clinics of North America, 2000
- DIGITAL IMAGING FOR DENTAL CARIESDental Clinics of North America, 2000
- THE FUTURE OF DIGITAL IMAGING IN DENTISTRYDental Clinics of North America, 2000
- Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiographyDentomaxillofacial Radiology, 2000
- An objective comparison of four digital intra-oral radiographic systems: sensitometric properties and resolutionDentomaxillofacial Radiology, 2000