Subpicosecond beam length measurement study based on themode
Authors:
- Zhichu ChenZCZhichu Chen
- Weimin ZhouWZWeimin Zhou
- Yongbin LengYLYongbin Leng
- Luyang YuLYLuyang Yu
- Renxian YuanRYRenxian Yuan
Open Access
- 1 July 2013
- journal article
- Published by American Physical Society (APS) in Physical Review Special Topics - Accelerators and Beams
- Vol. 16 (7)
Abstract
This article discusses a beam length measurement technique based on the TM_{010} modes of two cavities in frequency domain. Since the TM_{010} pickup monitor has a much better signal-to-noise ratio (SNR) than the other monitors, it can improve the measuring range and resolution limit of the beam length measurement in the frequency domain to achieve the real-time measurement of the pulse duration of the order of 1 ps or less with the resolution of about 10 fs. The root-mean-square length of a beam—which does not necessarily have a Gaussian distribution—can be obtained by choosing the working frequency of the cavity to be much less than the critical frequency of the beam. The modeling and analysis of the above theory were also made simultaneously. The resulting resolution was about 100 fs when the step size was chosen to be 200 fs in this simulation after the higher order mode coupling effect was eliminated and the beam offset was corrected by using the Bessel function. An efficient algorithm was also provided in case the measurement system would achieve the SNR of 112 dB when there could be some issue in signal processing. This algorithm can still provide the length result with the resolution of 3.5 μm for a beam duration of 0.1 ps when the SNR of the difference signal is as low as 10 dBKeywords
This publication has 13 references indexed in Scilit:
- Upconversion of a relativistic Coulomb field terahertz pulse to the near infraredApplied Physics Letters, 2010
- Electro-optic time profile monitors for femtosecond electron bunches at the soft x-ray free-electron laser FLASHPhysical Review Special Topics - Accelerators and Beams, 2009
- Benchmarking of Electro-Optic Monitors for Femtosecond Electron BunchesPhysical Review Letters, 2007
- Electro-Optic Technique with Improved Time Resolution for Real-Time, Nondestructive, Single-Shot Measurements of Femtosecond Electron Bunch ProfilesPhysical Review Letters, 2004
- Overall comparison of subpicosecond electron beam diagnostics by the polychromator, the interferometer and the femtosecond streak cameraNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- Single-Shot Electron-Beam Bunch Length MeasurementsPhysical Review Letters, 2002
- About transition radiation by relativistic electrons in a thin target in the millimeter range of wavesPhysics Letters A, 1999
- Measurement of femtosecond electron bunches using a rf zero-phasing methodPhysical Review E, 1998
- Nondestructive diagnostics for relativistic picosecond bunched electron beamsPhysical Review E, 1995