Understanding Physical Behaviors During Periods of Accelerometer Wear and Nonwear in College Students
- 1 December 2023
- journal article
- research article
- Published by Human Kinetics in Journal for the Measurement of Physical Behaviour
- Vol. 6 (4) , 298-314
Abstract
Accelerometers are increasingly used to measure 24-hr movement behaviors but are sometimes removed intermittently (e.g., for sleep or bathing), resulting in missing data. This study compared physical behaviors between times a hip-placed accelerometer was worn versus not worn in a college student sample. Participants (n = 115) wore a hip-placed ActiGraph during waking times and a thigh-placed activPAL continuously for at least 7 days (mean ± SD 7.5 ± 1.1 days). Thirteen nonwear algorithms determined ActiGraph nonwear; days included in the analysis had to have at least 1 min where the ActiGraph classified nonwear while participant was classified as awake by the activPAL. activPAL data for steps, time in sedentary behaviors (SB), light-intensity physical activity (LPA), and moderate- to vigorous-intensity physical activity (MVPA) from ActiGraph wear times were then compared with activPAL data from ActiGraph nonwear times. Participants took more steps (10.2–11.8 steps/min) and had higher proportions of MVPA (5.0%–5.9%) during ActiGraph wear time than nonwear time (3.1–8.0 steps/min, 0.8%–1.3% in MVPA). Effects were variable for SB (62.6%–66.9% of wear, 45.5%–76.2% of nonwear) and LPA (28.2%–31.5% of wear, 23.0%–53.2% of nonwear) depending on nonwear algorithm. Rescaling to a 12-hr day reduced SB and LPA error but increased MVPA error. Requiring minimum wear time (e.g., 600 min/day) reduced error but resulted in 10%–22% of days removed as invalid. In conclusion, missing data had minimal effect on MVPA but resulted in underestimation of SB and LPA. Strategies like scaling SB and LPA, but not MVPA, may improve physical behavior estimates from incomplete accelerometer data.Keywords
This publication has 44 references indexed in Scilit:
- Separating Movement and Gravity Components in an Acceleration Signal and Implications for the Assessment of Human Daily Physical ActivityPLOS ONE, 2013
- Identifying sedentary time using automated estimates of accelerometer wear timeBritish Journal of Sports Medicine, 2011
- Validation of Accelerometer Wear and Nonwear Time Classification AlgorithmMedicine & Science in Sports & Exercise, 2011
- A Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity MonitoringSensors, 2010
- Sleep Patterns and Predictors of Disturbed Sleep in a Large Population of College StudentsJournal of Adolescent Health, 2010
- Estimates of adherence and error analysis of physical activity data collected via accelerometry in a large study of free-living adultsBMC Medical Research Methodology, 2008
- Simple imputation methods were inadequate for missing not at random (MNAR) quality of life dataHealth and Quality of Life Outcomes, 2008
- Physical Activity in the United States Measured by AccelerometerMedicine & Science in Sports & Exercise, 2008
- Accelerometer Data Reduction: A Comparison of Four Reduction Algorithms on Select Outcome VariablesMedicine & Science in Sports & Exercise, 2005
- Imputation of Missing Data When Measuring Physical Activity by AccelerometryMedicine & Science in Sports & Exercise, 2005