Bacterial contamination of ready-to-use 1-L feeding bottles and administration sets in severely compromised intensive care patients
Authors:
- Jan M. BinnekadeJBJan M. Binnekade
- Rob J. de HaanRHRob J. de Haan
- 1 January 2000
- journal article
- research article
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 28 (1) , 67-73
Abstract
In intensive care patients, enteral feeding requires sterile feedings because of infectious complications and adequate supplements to meet nutritional needs. Heretofore, prepacked, large-volume formula containers were developed, but bacterial contamination occurred in 4% to 15%. Our objective was to investigate the microbial contamination rate of 1-L feeding bottles and newly designed administration sets over hanging times of 24 hrs in the intensive care unit (ICU). A prospective observational cohort study of patients admitted to the ICU of a university hospital. All consecutive patients fed via a nasojejunal tube for at least 4 days. Cultures of feeding bottles, administration sets, and gastric and tracheobronchial aspirates at day 0, 1, 2, 4, and 7. A total of 4% of feeding bottles and 74% of infusion sets contained >102 colony forming units (CFU)/mL. Gastric and bronchial aspirates were positive in 90% and 92%, respectively. Bacterial counts of feeding bottles were 102-105 CFU/mL, and the main bacteria isolated included Enterobacter cloacae, Klebsiella oxytoca, and enterococci. One third of all cultured bacteria in feeding bottles, administration sets, stomach, and lungs belonged to the Enterobacteriaceae family, which was held responsible for the nosocomial infections in the ICU. None of the 1-L feeding bottles with a hanging time of 19-24 hrs was contaminated. Only bottles that had to be exchanged because of need for a faster rate of infusion proved to be contaminated, apparently without clinical consequences. With time and the increasing severity of disease, the administration sets became contaminated at an increasingly faster rate and with higher bacterial counts mainly through retrograde growth of endogenous bacteria. The final step of bottle contamination might have been the bacterial transfer by nurses' hands. Despite an almost ideal design of the enteral nutrition delivery system, a 4% contamination rate of initially sterile feedings with clinically relevant bacteria and the fact that only manipulated systems showed bacterial growth are of concern.Keywords
This publication has 28 references indexed in Scilit:
- Contamination of a Prefilled Ready‐to‐Use Enteral Feeding System Compared With a Refillable BagJournal of Parenteral and Enteral Nutrition, 1993
- Bacterial contamination of enteral feeds and feeding systemsClinical Nutrition, 1993
- Retrograde (Ascending) Bacterial Contamination of Enteral Diet Administration SystemsJournal of Parenteral and Enteral Nutrition, 1992
- Contaminated Enteral Nutrition Solutions as a Cause of Nosocomial Bloodstream Infection: A Study Using Plasmid FingerprintingJournal of Parenteral and Enteral Nutrition, 1989
- Microbial Contamination of Continuous Drip FeedingsJournal of Parenteral and Enteral Nutrition, 1989
- The effect of handling procedures on bacterial contamination of enteral feeds—importance of design of enteral feeding setsJournal of Human Nutrition and Dietetics, 1988
- Clinical evaluation of two‐liter prepacked enteral diet delivery system: a controlled trialJournal of Parenteral and Enteral Nutrition, 1988
- The effect of handling procedures on microbial contamination of enteral feedsJournal of Hospital Infection, 1988
- Microbial growth in clinically used enteral delivery systemsAmerican Journal of Infection Control, 1986
- A controlled trial of aseptic enteral diet preparation — Significant effects on bacterial contamination and nitrogen balanceClinical Nutrition, 1983