A Reference-Wavelength-Based Method for Improved Analysis of Near-Infrared Spectroscopy
Authors:
- 1 May 2009
- journal article
- research article
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 63 (5) , 544-548
Abstract
Near-infrared (NIR) spectroscopy has been widely used in many industrial applications. It also has tremendous potential for trace element detection and noninvasive human physiological measurements. In NIR spectroscopy, however, the measurement precision is often dependent on temperature, measurement position, and sample status. In order to improve measurement precision, a method using spectral information at a reference wavelength is developed in this paper. Based on the displacement effect between solvent and solute molecules in a solution, the signal at the reference wavelength is used as an internal reference to correct the spectrum of the sample under test. As an example, the spectra of glucose aqueous solutions under different temperatures are measured, and our method for eliminating the temperature disturbance is evaluated. The experimental results obtained show that the relative error of glucose concentration prediction is 330% per degree before the spectrum correction. After the correction, the relative error is reduced to 5.12%, and the error is no longer dependent on temperature. As the displacement effect can be found commonly in various solutions, the method described in this work may be used to improve the accuracy of spectral analysis of many other solutions.Keywords
This publication has 16 references indexed in Scilit:
- On-Line Near-Infrared Spectrometer to Monitor Urea Removal in Real Time during HemodialysisApplied Spectroscopy, 2008
- Blank Augmentation Protocol for Improving the Robustness of Multivariate CalibrationsApplied Spectroscopy, 2007
- Broadband diffuse optical spectroscopy measurement of hemoglobin concentration during hypovolemia in rabbitsPhysiological Measurement, 2006
- New Methodology to Obtain a Calibration Model for Noninvasive Near-Infrared Blood Glucose MonitoringApplied Spectroscopy, 2006
- Development of a PLS based method for determination of the quality of beers by use of NIR: spectral ranges and sample-introduction considerationsAnalytical and Bioanalytical Chemistry, 2005
- The Use of Visible and near Infrared Spectroscopy to Classify the Floral Origin of Honey Samples Produced in UruguayJournal of Near Infrared Spectroscopy, 2005
- Simulation study ofin vitroglucose measurement by NIR spectroscopy and a method of error reductionPhysics in Medicine & Biology, 2003
- Influence of Temperature on Water and Aqueous Glucose Absorption Spectra in the Near- and Mid-Infrared Regions at Physiologically Relevant TemperaturesApplied Spectroscopy, 2003
- Real-time classification of petroleum products using near-infrared spectraComputers & Chemical Engineering, 2000
- An interpretation of the evolution with temperature of the ν2+ν3 combination band in waterThe Journal of Chemical Physics, 1978