Low-background thick-walled gas-electron multiplier for measuring alpha-, beta-, and X-rays of ultralow intensity
- 1 July 2010
- journal article
- Published by Pleiades Publishing Ltd in Technical Physics Letters
- Vol. 36 (7) , 592-594
Abstract
An experimental prototype of thick-walled gas-electron multiplier (THGEM) has been designed and manufactured using metal-coated fluoroplast as a low-background material. Working characteristics of the proposed device have been measured in detecting alpha-, beta-, and X-rays of ultralow intensity. Based on these data, the design of a low-background THGEM is developed for operating in the regime of counting single-electron pulses.Keywords
This publication has 6 references indexed in Scilit:
- BoNus: Development and use of a radial TPC using cylindrical GEMsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2008
- Development of a GEM-based High Resolution TPC for the ILCNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2007
- ArDM: a ton-scale liquid Argon experiment for direct detection of Dark Matter in the UniverseJournal of Physics: Conference Series, 2006
- A Scintillating Triple GEM Beam Monitor for Radiation Therapy2006
- Upgrade of the KEDR tagging systemNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2002
- GEM: A new concept for electron amplification in gas detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1997