Genauigkeit eines bildfreien Navigationssystemes für die Hüftpfannenimplantation – eine anatomische Studie / Accuracy of an Image-free Cup Navigation System – an Anatomical Study
Open Access
- 1 January 2004
- journal article
- research article
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 49 (9) , 257-262
Abstract
The position of the acetabular cup is of decisive importance for the function of a total hip replacement (THR). Using the conventional surgical technique, correct placement of the cup often fails due to a lack of information about pelvic tilt. With CT-based and fluoroscopically-assisted navigation procedures the accuracy of implantation has been significantly improved. However, additional radiation exposure, high cost and the increased time requirement have hampered the acceptance of these techniques. The present anatomical study evaluates the accuracy of an alternative procedure--image-free navigation. This method requires little extra effort, does not substantially delay surgery, and needs no additional imaging. Press-fit cups were implanted in 10 human cadaveric hips with the help of the image-free navigation system, and the position of the cups was checked intraoperatively with a CT-based navigation system and postoperatively by computed tomography. All cups were implanted within the targeted safe zone with an average inclination of 44 degrees (range 40 degrees-48 degrees, SABW 2.7 degrees) and an average anteversion of 18 degrees (range 12-24 degrees, SABW 4.1 degrees). Analysis of accuracy of the image-free navigation software revealed only a small, clinically tolerable deviation in cup anteversion and cup inclination in comparison with the CT-based navigation system and the post operative CT scans. The evaluated image-free navigation system appears to be a practicable and reliable alternative to the computer-assisted implantation of acetabular cups in total hip arthroplasty.Keywords
This publication has 14 references indexed in Scilit:
- Mini-incision technique for total hip arthroplasty with navigationThe Journal of Arthroplasty, 2003
- Computerassistierte Hüftpfannennavigation bei primär- und sekundär dysplastischen AusgangssituationenZeitschrift für Orthopädie und ihre Grenzgebiete, 2003
- A hybrid CT-free navigation system for total hip arthroplastyComputer Aided Surgery, 2002
- Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized studyComputer Aided Surgery, 2002
- Comparison of a mechanical acetabular alignment guide with computer placement of the socketThe Journal of Arthroplasty, 2002
- Anwendung eines CAS-Systems in der Arthroskopischen Kreuzbandchirurgie - Adaption und Applikation in der klinischen PraxisZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- Image Guided Navigation System to Measure Intraoperatively Acetabular Implant AlignmentClinical Orthopaedics and Related Research, 1998
- Effects of acetabular abduction on cup wear rates in total hip arthroplastyThe Journal of Arthroplasty, 1998
- Über die Bedeutung der Position der Endoprothesenpfanne aus biomechanischer und klinischer Sicht-Vorschlag einer Klassifizierung - Remarks on the Biomechanical and Clinical Significance of the Positioning of the Acetabular Cup - Proposal for a ClassificationBiomedical Engineering / Biomedizinische Technik, 1994
- Prognosis of total hip replacement in Sweden: Follow-up of 92,675 operations performed 1978–1990Acta Orthopaedica, 1993