Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective from the American Contact Dermatitis Society
- 1 October 2016
- journal article
- review article
- Published by SAGE Publications in Dermatitis®
- Vol. 27 (5) , 241-247
Abstract
The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion–based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.Keywords
This publication has 48 references indexed in Scilit:
- Particle disease: Biologic mechanisms of periprosthetic osteolysis in total hip arthroplastyInnate Immunity, 2012
- What proportion of patients report long-term pain after total hip or knee replacement for osteoarthritis? A systematic review of prospective studies in unselected patientsBMJ Open, 2012
- Hypersensitivity reactions to metallic implants – diagnostic algorithm and suggested patch test series for clinical useContact Dermatitis, 2011
- No association between metal allergy and cardiac in-stent restenosis in patients with dermatitis-results from a linkage studyContact Dermatitis, 2011
- Increased metal allergy in patients with failed metal‐on‐metal hip arthroplasty and peri‐implant T‐lymphocytic inflammationAllergy, 2009
- A correlation found between contact allergy to stent material and restenosis of the coronary arteriesContact Dermatitis, 2009
- Th1 type lymphocyte reactivity to metals in patients with total hip arthroplastyJournal of Orthopaedic Surgery and Research, 2008
- High frequency of contact allergy to gold in patients with endovascular coronary stentsBritish Journal of Dermatology, 2007
- When it is not an infection: metal allergy after the Nuss procedure for repair of pectus excavatumJournal of Pediatric Surgery, 2007
- Nickel release after implantation of the Amplatzer occluderAmerican Heart Journal, 2003