Feasibility of a Selective Epoxidation Technique for Use in Quantification of Peracetic Acid in Air Samples Collected on Sorbent Tubes
- 23 June 2022
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Chemical Health & Safety
- Vol. 29 (4) , 378-386
Abstract
Peracetic acid is a disinfection agent used in medical and food processing facilities, and occupational exposures have been documented. To facilitate characterization of daily occupational exposures, the current work describes the development of a personal sampling technique to quantify the peracetic acid concentration in air samples. Peracetic acid atmospheres were generated in 100 L Teflon chambers, and samples were collected on 350 mg XAD-7 solid sorbent tubes for 4 h at a flow rate of 250 mL/min using a personal sampling pump. Indirect measurement of peracetic acid was achieved by desorption from the sorbent and subsequent treatment with cyclohexene to initiate an epoxidation reaction, formally known as the Prilezhaev reaction. The epoxidation product, cyclohexene oxide, was quantified by gas chromatography–mass spectrometry. The reaction enabled quantification of peracetic acid with high specificity over the common co-contaminants hydrogen peroxide and acetic acid, which were introduced in 10-fold and 100-fold excess to challenge the reaction. The technique also demonstrated an overall estimate of bias and precision of 11 and 8%, respectively, and a limit of detection of 60 ppbv was estimated. Preliminary storage experiments indicate that unreacted peracetic acid is stable on the sorbent tubes for 72 h when stored at −20 °C following collection. Overall, the specificity of the reaction and capability to sample for longer time periods than current methods, in addition to the use of safer personal sampling materials, demonstrate the utility of this technique for peracetic acid measurement in air.Keywords
Funding Information
- National Institute for Occupational Safety and Health
This publication has 38 references indexed in Scilit:
- A Review of Current Disinfectants for Gastrointestinal Endoscopic ReprocessingClinical Endoscopy, 2013
- Review: Efficiency of Physical and Chemical Treatments on the Inactivation of Dairy BacteriophagesFrontiers in Microbiology, 2012
- Passive Sampling of Airborne Peroxyacetic AcidAnalytical Chemistry, 2006
- Gas-Phase Chemistry of α-Terpineol with Ozone and OH Radical: Rate Constants and ProductsEnvironmental Science & Technology, 2005
- Simultaneous Sampling of Peroxyacetic Acid and Hydrogen Peroxide in Workplace AtmospheresAnnals of Occupational Hygiene, 2004
- Disinfection of Endoscopes: Review of New Chemical Sterilants Used for High-Level DisinfectionInfection Control & Hospital Epidemiology, 1999
- Selective Photometric Determination of Peroxycarboxylic Acids in the Presence of Hydrogen PeroxideThe Analyst, 1997
- Rapid high-performance liquid chromatographic method for the determination of peroxyacetic acidJournal of Chromatography A, 1996
- Summary of the NIOSH guidelines for air sampling and analytical method development and evaluationThe Analyst, 1996
- Organic Peracids.Chemical Reviews, 1949