Motion-compensated compressed sensing for dynamic contrast-enhanced MRI using regional spatiotemporal sparsity and region tracking: Block low-rank sparsity with motion-guidance (BLOSM)
Open Access
- 18 November 2013
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 72 (4) , 1028-1038
Abstract
Purpose Dynamic contrast‐enhanced MRI of the heart is well‐suited for acceleration with compressed sensing (CS) due to its spatiotemporal sparsity; however, respiratory motion can degrade sparsity and lead to image artifacts. We sought to develop a motion‐compensated CS method for this application. Methods A new method, Block LOw‐rank Sparsity with Motion‐guidance (BLOSM), was developed to accelerate first‐pass cardiac MRI, even in the presence of respiratory motion. This method divides the images into regions, tracks the regions through time, and applies matrix low‐rank sparsity to the tracked regions. BLOSM was evaluated using computer simulations and first‐pass cardiac datasets from human subjects. Using rate‐4 undersampling, BLOSM was compared with other CS methods such as k‐t SLR that uses matrix low‐rank sparsity applied to the whole image dataset, with and without motion tracking, and to k‐t FOCUSS with motion estimation and compensation that uses spatial and temporal‐frequency sparsity. Results BLOSM was qualitatively shown to reduce respiratory artifact compared with other methods. Quantitatively, using root mean squared error and the structural similarity index, BLOSM was superior to other methods. Conclusion BLOSM, which exploits regional low‐rank structure and uses region tracking for motion compensation, provides improved image quality for CS‐accelerated first‐pass cardiac MRI. Magn Reson Med 72:1028–1038, 2014.Keywords
This publication has 42 references indexed in Scilit:
- Motion-adaptive spatio-temporal regularization for accelerated dynamic MRIMagnetic Resonance in Medicine, 2012
- Accelerated contrast‐enhanced whole‐heart coronary MRI using low‐dimensional‐structure self‐learning and thresholdingMagnetic Resonance in Medicine, 2012
- Fast $\ell_1$-SPIRiT Compressed Sensing Parallel Imaging MRI: Scalable Parallel Implementation and Clinically Feasible RuntimeIEEE Transactions on Medical Imaging, 2012
- Motion compensated reconstruction for myocardial perfusion MRIJournal of Cardiovascular Magnetic Resonance, 2012
- Accelerated phase‐contrast cine MRI using k‐t SPARSE‐SENSEMagnetic Resonance in Medicine, 2011
- A reproducible evaluation of ANTs similarity metric performance in brain image registrationNeuroImage, 2011
- Combination of compressed sensing and parallel imaging for highly accelerated first‐pass cardiac perfusion MRIMagnetic Resonance in Medicine, 2010
- SPIRiT: Iterative self‐consistent parallel imaging reconstruction from arbitrary k‐spaceMagnetic Resonance in Medicine, 2010
- Acquisition and reconstruction of undersampled radial data for myocardial perfusion magnetic resonance imagingJournal of Magnetic Resonance Imaging, 2009
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999