Computer-Aided Intraoperative Toric Intraocular Lens Positioning and Alignment During Cataract Surgery
- 9 April 2021
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (10) , 3921-3932
Abstract
Cataract causes more than half of all blindness worldwide. The most effective treatment is surgery, where cataract is often replaced by intraocular lens (IOL). Beyond saving vision, toric IOL implantation is becoming increasingly popular to correct corneal astigmatism. It is important to precisely position and align the axis of IOL during surgery to achieve optimal post-operative astigmatism correction. Comparing with conventional manual marking, automated markerless IOL alignment can be faster, more accurate and non-invasive. Here we propose a framework for computer-assisted intraoperative IOL positioning and alignment based on detection and tracking. Firstly, the iris boundary was segmented and the eye center was determined. A statistical sampling method was developed to segment iris and generate training labels, and both conventional algorithms and deep convolutional neural network (CNN) methods were evaluated. Then, regions of interests (ROIs) containing high density of scleral capillaries were used for tracking eye rotations. Both correlation filter and CNN methods were evaluated for tracking. Cumulative errors during long-term tracking were corrected using a reference image. Validation studies against manual labeling using 7 clinical cataract surgical videos demonstrated that the proposed algorithm achieved an average position error around 0.2 mm, an axis alignment error of < 1 $^{\circ}$ , and a frame rate of > 25 FPS, and can be potentially used intraoperatively for markerless IOL positioning and alignment during cataract surgery.Keywords
Funding Information
- National Natural Science Foundation of China (61921002, 62075033)
- Sichuan Science and Technology Program (2020YFS0076)
This publication has 35 references indexed in Scilit:
- Multifocal versus monofocal intraocular lenses after cataract extraction2012
- Simple and accurate alignment of toric intraocular lenses and evaluation of their rotation errors using anterior segment optical coherence tomographyJapanese Journal of Ophthalmology, 2011
- Residual astigmatism produced by toric intraocular lens rotationJournal of Cataract & Refractive Surgery, 2011
- Femtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence TomographyScience Translational Medicine, 2010
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Adaptive Thresholding using the Integral ImageJournal of Graphics Tools, 2007
- Hyperopic shift in refraction associated with implantation of the single-piece Collamer intraocular lensJournal of Cataract & Refractive Surgery, 2006
- Capsulorhexis size and posterior capsule opacificationJournal of Cataract & Refractive Surgery, 1996
- Detection of blood vessels in retinal images using two-dimensional matched filtersIEEE Transactions on Medical Imaging, 1989
- A fast parallel algorithm for thinning digital patternsCommunications of the ACM, 1984