How reliable is visual assessment of the electrically elicited stapedius reflex threshold during cochlear implant surgery, compared with tympanometry?
Authors:
- 5 November 2010
- journal article
- research article
- Published by Cambridge University Press (CUP) in The Journal of Laryngology & Otology
- Vol. 125 (3) , 271-273
Abstract
Objectives: To assess the reliability of visually assessed thresholds of the electrically elicited stapedius reflex, recorded during cochlear implant surgery, compared with intra-operative tympanometric threshold assessment. Intra-operatively recorded electrically elicited stapedius reflex thresholds vary considerably, and differ from those measured post-operatively by means of impedance changes (i.e. using tympanometry). Thus, any confounding effect of different intra-operative techniques and visual assessment inaccuracies should be excluded.Methods: Both techniques (i.e. visual observation and tympanometry) were performed intra-operatively in six patients, and threshold values were compared.Results: Recorded electrically elicited stapedius reflex thresholds were very similar for both techniques. Visually assessed thresholds were slightly higher in some cases and lower in others, compared with tympanometric thresholds.Discussion: There was almost no difference between reflex thresholds measured with the two different techniques under the same intra-operative conditions. Therefore, we conclude that differences between intra- and post-operative thresholds are not due to the use of different measuring techniques. The main reason for such differences is probably the influence of intra-operative narcotics on reflex thresholds.Keywords
This publication has 13 references indexed in Scilit:
- Dose-Dependent Suppression of the Electrically Elicited Stapedius Reflex by General Anesthetics in Children Undergoing Cochlear Implant SurgeryAnesthesia & Analgesia, 2009
- Electromyographical Recording of the Electrically Elicited Stapedius Reflex via a Bipolar Hook ElectrodeOtology & Neurotology, 2009
- Relationships among objective measures and speech perception in adult users of the HiResolution Bionic EarCochlear Implants International, 2008
- Relationships among objective measures and speech perception in adult users of the HiResolution Bionic EarCochlear Implants International, 2008
- Characteristics of stapedius muscle electromyograms elicited by cochlear implant stimulation in the rat2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Investigations into electrically evoked stapedius reflex measures and subjective loudness percepts in the MED-EL COMBI 40+ cochlear implantCochlear Implants International, 2005
- ESRT and MCL correlations in experienced paediatric cochlear implant usersCochlear Implants International, 2004
- ESRT and MCL correlations in experienced paediatric cochlear implant usersCochlear Implants International, 2004
- Intraoperative Electrically Elicited Stapedius Reflex Threshold is Related to the Dosage of Hypnotic Drugs in General AnesthesiaAnnals of Otology, Rhinology & Laryngology, 2003
- Ojective Intraoperative Method to Record Averaged Electromyographic Stapedius Muscle Reflexes in Cochlear Implant Patients: Metodo objetivo transoperatorio para el registro electromiográfico promediado de los reflejos del müAsculo estapedial en pacientes con implante coclearInternational Journal of Audiology, 2000