CT angiography in highly calcified arteries: 2D manual vs. modified automated 3D approach to identify coronary stenoses
- 15 March 2006
- journal article
- research article
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 22 (3) , 507-516
Abstract
Two-dimensional axial and manually-oriented reformatted images are traditionally used to analyze coronary data provided by multidetector-row computed tomography angiography (MDCTA). While apparently more accurate in evaluating calcified vessels, 2D methods are time-consuming compared with automated 3D approaches. The purpose of this study was to evaluate the performance of a modified automated 3D approach (using manual vessel isolation and different window and level settings) in a population with high calcium scores who underwent coronary half-millimeter 16-detector-row CT angiography (16×0.5-MDCTA). ECG-gated 16×0.5-MDCTA (16×0.5 mm cross-sections, 0.35×0.35×0.35 mm3 isotropic voxels, 400 ms rotation) was performed after injection of iopamidol (120-ml, 300 mg/ml) in 19 consecutive patients (11 male, 62±10 years-old). Native arteries were independently evaluated for ≥50%-stenoses using both manual 2D and modified automated 3D approaches. Stents and bypass grafts were excluded. Conventional coronary angiography was visually analyzed by 2 observers. Median Agatston calcium score was 434. Sensitivities, specificities, positive and negative predictive values for detection of ≥50% coronary stenoses using the 2D and modified 3D approaches were, respectively: 74%/63%, 76%/80%, 45%/34%, and 91%/93% (p=NS for all comparisons). Overall diagnostic accuracies were 75 and 78%, respectively (p=NS). Uninterpretable vessels were, respectively: 37% (77/209) and 35% (73/209) – p=NS. Time to analyze a single study was 160±23 and 53±11 min, respectively (p<0.01). This modified automated 3D approach is equivalent to and significantly less time consuming than the traditional manual 2D method for evaluation of ≥50%-stenoses by 16×0.5-MDCTA in native coronary arteries of patients with high calcium scores.Keywords
This publication has 13 references indexed in Scilit:
- Predictive Value of 16-Slice Multidetector Spiral Computed Tomography to Detect Significant Obstructive Coronary Artery Disease in Patients at High Risk for Coronary Artery DiseaseCirculation, 2004
- Multislice CT Coronary Angiography: Evaluation of an Automatic Vessel Detection ToolRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 2004
- Multisegment and Halfscan Reconstruction of 16-Slice Computed Tomography for Detection of Coronary Artery StenosesInvestigative Radiology, 2004
- Diagnostic accuracy of multidetector computed tomography coronary angiography in patients with angiographically proven coronary artery diseaseJACC, 2004
- Detection of Coronary Artery Stenoses With Thin-Slice Multi-Detector Row Spiral Computed Tomography and Multiplanar ReconstructionCirculation, 2003
- Reliable Noninvasive Coronary Angiography With Fast Submillimeter Multislice Spiral Computed TomographyCirculation, 2002
- American College of Cardiology/Society for Cardiac Angiography and Interventions Clinical Expert Consensus Document on Cardiac Catheterization Laboratory Standards41When citing this document, the American College of Cardiology and the Society for Cardiac Angiography and Interventions would appreciate the following citation format: Bashore TM, Bates ER, Berger PB, Clark DA, Cusma JT, Dehmer GJ, Kern MJ, Laskey WK, O’Laughlin MP, Oesterle S, Popma JJ. Cardiac catheterization laboratory standards: a report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents (ACC/SCA&I Committee to Develop an Expert Consensus Document on Cardiac Catheterization Laboratory Standards). J Am Coll Cardiol 2001;37:2170–214.44Address for reprints: This document is available on the Web sites of the American College of Cardiology (http://www.acc.org) and the Society for Cardiac Angiography and Interventions (http://www.scai.org). Reprints of this document may be purchased for $5 each by calling 1-800-253-4636, ext 694, or by writing to the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, MD 20814-1699.JACC, 2001
- Natural History and Topographic Pattern of Progression of Coronary Calcification in Symptomatic PatientsArteriosclerosis, Thrombosis, and Vascular Biology, 2001
- Coronary angiography with multi-slice computed tomographyThe Lancet, 2001
- Quantification of coronary artery calcium using ultrafast computed tomographyJACC, 1990