A Comparison between QLAB and TomTec Full Volume Reconstruction for Real Time Three‐Dimensional Echocardiographic Quantification of Left Ventricular Volumes
- 30 May 2007
- journal article
- research article
- Published by Wiley in Echocardiography
- Vol. 24 (9) , 967-974
Abstract
Objectives: To compare the interobserver variability and accuracy of two different real time three‐dimensional echocardiography (RT3DE) analyzing programs. Methods: Forty‐one patients (mean age 56 ± 11 years, 28 men) in sinus rhythm with a cardiomyopathy and adequate 2D image quality underwent RT3DE and magnetic resonance imaging (MRI) within one day. Off‐line left ventricular (LV) volume analysis was performed with QLAB V4.2 (semiautomated border detection with biplane projections) and TomTec 4D LV analysis V2.0 (primarily manual tracking with triplane projections and semiautomated border detection). Results: Excellent correlations (R2 > 0.98) were found between MRI and RT3DE. Bland–Altman analysis revealed an underestimated LV end‐diastolic volume (LV‐EDV) for both TomTec (−9.4 ± 8.7 mL) and QLAB (−16.4 ± 13.1 ml). Also, an underestimated LV end‐systolic volume (LV‐ESV) for both TomTec (−4.8 ± 9.9 mL) and QLAB (−8.5 ± 14.2 mL) was found. LV‐EDV and LV‐ESV were significantly more underestimated with QLAB software. Both programs accurately calculated LV ejection fraction (LV‐EF) without a bias. Interobserver variability was 6.4 ± 7.8% vs. 12.2 ± 10.1% for LV‐EDV, 7.8 ± 9.7% vs. 13.6 ± 11.2% for LV‐ESV, and 7.1 ± 6.9% vs. 9.7 ± 8.8% for LV‐EF for TomTec vs. QLAB, respectively. The analysis time was shorter with QLAB (4 ± 2 minutes vs. 6 ± 2 minutes, P < 0.05). Conclusions: RT3DE with TomTec or QLAB software analysis provides accurate LV‐EF assessment in cardiomyopathic patients with distorted LV geometry and adequate 2D image quality. However, LV volumes may be somewhat more underestimated with the current QLAB software version.Keywords
This publication has 19 references indexed in Scilit:
- Accuracy and Feasibility of Online 3-Dimensional Echocardiography for Measurement of Left Ventricular ParametersJournal of the American Society of Echocardiography, 2006
- Rapid and Accurate Measurement of Left Ventricular Function with a New Second‐Harmonic Fast‐Rotating Transducer and Semi‐Automated Border DetectionEchocardiography, 2006
- Contemporary Definitions and Classification of the CardiomyopathiesCirculation, 2006
- Real-Time Transthoracic Three-Dimensional Echocardiographic Assessment of Left Ventricular Volume and Ejection Fraction in Congenital Heart DiseaseJournal of the American Society of Echocardiography, 2006
- Rapid full volume data acquisition by real-time 3-dimensional echocardiography for assessment of left ventricular indexes in children: A validation study compared with magnetic resonance imagingJournal of the American Society of Echocardiography, 2005
- Comparison of left ventricular volumes and ejection fractions measured by three-dimensional echocardiography versus by two-dimensional echocardiography and cardiac magnetic resonance in patients with various cardiomyopathiesThe American Journal of Cardiology, 2005
- Reproducibility and accuracy of echocardiographic measurements of left ventricular parameters using real-time three-dimensional echocardiographyJACC, 2004
- ClassifiedsJournal of the American Society of Echocardiography, 2003
- Three-dimensional echocardiography improves noninvasive assessment of left ventricular volume and performanceAmerican Heart Journal, 1995
- STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENTThe Lancet, 1986