Torso-Tank Validation of High-Resolution Electrogastrography (EGG): Forward Modelling, Methodology and Results
Authors:
- 27 April 2018
- journal article
- research article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (8) , 1183-1193
Abstract
Electrogastrography (EGG) is a non-invasive method for measuring gastric electrical activity. Recent simulation studies have attempted to extend the current clinical utility of the EGG, in particular by providing a theoretical framework for distinguishing specific gastric slow wave dysrhythmias. In this paper we implement an experimental setup called a ‘torso-tank’ with the aim of expanding and experimentally validating these previous simulations. The torso-tank was developed using an adult male torso phantom with 190 electrodes embedded throughout the torso. The gastric slow waves were reproduced using an artificial current source capable of producing 3D electrical fields. Multiple gastric dysrhythmias were reproduced based on high-resolution mapping data from cases of human gastric dysfunction (gastric re-entry, conduction blocks and ectopic pacemakers) in addition to normal test data. Each case was recorded and compared to the previously-presented simulated results. Qualitative and quantitative analyses were performed to define the accuracy showing \(\sim \) 1.8% difference, \(\sim \) 0.99 correlation, and \(\sim \) 0.04 normalised RMS error between experimental and simulated findings. These results reaffirm previous findings and these methods in unison therefore present a promising morphological-based methodology for advancing the understanding and clinical applications of EGG.
Keywords
Funding Information
- Health Research Council of New Zealand
- Medical Technologies Centre of Research Excellence
- Alexander von Humboldt-Stiftung (Fraunhofer-Bessel Research Award)
- Royal Society of New Zealand (Rutherford Discovery Fellowship)
- University of Auckland (Andrew Pullan Doctoral Scholarship)
This publication has 36 references indexed in Scilit:
- Interstitial cells of Cajal, from structure to functionFrontiers in Neuroscience, 2013
- A Multiscale Model of the Electrophysiological Basis of the Human ElectrogastrogramBiophysical Journal, 2010
- Origin and propagation of human gastric slow-wave activity defined by high-resolution mappingAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2010
- The localization of focal heart activity via body surface potential measurements: tests in a heterogeneous torso phantomPhysics in Medicine & Biology, 2009
- Interstitial cells of Cajal in health and diseaseNeurogastroenterology & Motility, 2008
- Mathematical models and numerical methods for the forward problem in cardiac electrophysiologyComputing and Visualization in Science, 2002
- Gastrin Stimulates Histamine Release from the Isolated Pig StomachScandinavian Journal of Gastroenterology, 1997
- Human electrogastrogramsDigestive Diseases and Sciences, 1986
- The Electrocardiographic Leads for Telemetering as Evaluated from View Point of the Transfer Impedance VectorJapanese Heart Journal, 1970
- The Influence of the Inhomogeneities of Electrical Conductivity within the Torso on the Electrocardiogram as Evaluated from the View Point of the Transfer Impedance VectorJapanese Heart Journal, 1970