Myocardial infarction biomarker C‐reactive protein detection on nanocomposite aptasensor
- 28 December 2020
- journal article
- research article
- Published by Wiley in Biotechnology and Applied Biochemistry
- Vol. 69 (1) , 166-171
Abstract
Myocardial infarction (MI) is considered as one of the major life‐threatening health issues worldwide. Growing number of cases every year is demanding rapid, portable, and early detection by the sensing devices for the identification of MI. This research work introduces a modified interdigitated electrode (IDE) sensing surface constructed with single‐walled carbon nanotube (SWCN) to detect the cardiac biomarker, C‐reactive protein (CRP). CRP‐specific aptamer was conjugated with gold nanoparticle and attached on SWCN‐constructed IDE surface. This probe‐modified sensing surface has reached the limit of CRP detection to 10 pM on a linear regression curve with the regression coefficient of R² = 0.9223 [y = 0.9198x − 0.4326]. Further, control molecules, such as random aptamer sequence and nontarget cardiac biomarker (Troponin I), did not show the current response, indicating the specific CRP detection. This sensing strategy helps to detect the lower level of CRP and diagnose the MI at its earlier stages.Keywords
This publication has 22 references indexed in Scilit:
- Detection of Aβ Monomers and Oligomers: Early Diagnosis of Alzheimer's DiseaseChemistry – An Asian Journal, 2016
- Ultrasensitive Colorimetric Detection of 17β-Estradiol: The Effect of Shortening DNA Aptamer SequencesAnalytical Chemistry, 2015
- Nanomaterials for biosensing applications: a reviewFrontiers in Chemistry, 2014
- Co-immobilized poly(ethylene glycol)-block-polyamines promote sensitivity and restrict biofouling on gold sensor surface for detecting factor IX in human plasmaThe Analyst, 2014
- Colorimetric detection of controlled assembly and disassembly of aptamers on unmodified gold nanoparticlesBiosensors and Bioelectronics, 2014
- In vivo biosensing via tissue-localizable near-infrared-fluorescent single-walled carbon nanotubesNature Nanotechnology, 2013
- A high-performance waveguide-mode biosensor for detection of factor IX using PEG-based blocking agents to suppress non-specific binding and improve sensitivityThe Analyst, 2013
- Construction of a densely poly(ethylene glycol)-chain-tethered surface and its performancePolymer Journal, 2011
- Detection of C Reactive Protein (CRP) in Serum by an Electrochemical Aptamer‐Based Sandwich AssayElectroanalysis, 2009
- Functionalization and Dissolution of Single-Walled Carbon Nanotubes by Chemical-Physical and Electrochemical TreatmentsMicrochimica Acta, 2005