Reconstruction of a high‐quality volumetric image and a respiratory motion model from patient CBCT projections
- 13 May 2019
- journal article
- research article
- Published by Wiley in Medical Physics
- Vol. 46 (8) , 3627-3639
Abstract
Purpose: To develop and evaluate a method of reconstructing a patient‐ and treatment day‐ specific volumetric image and motion model from free‐breathing cone‐beam projections and respiratory surrogate measurements. This Motion‐Compensated Simultaneous Algebraic Reconstruction Technique (MC‐SART) generates and uses a motion model derived directly from the cone‐beam projections, without requiring prior motion measurements from 4DCT, and can compensate for both inter‐ and intrabin deformations. The motion model can be used to generate images at arbitrary breathing points, which can be used for estimating volumetric images during treatment delivery.Methods: The MC‐SART was formulated using simultaneous image reconstruction and motion model estimation. For image reconstruction, projections were first binned according to external surrogate measurements. Projections in each bin were used to reconstruct a set of volumetric images using MC‐SART. The motion model was estimated based on deformable image registration between the reconstructed bins, and least squares fitting to model parameters. The model was used to compensate for motion in both projection and backprojection operations in the subsequent image reconstruction iterations. These updated images were then used to update the motion model, and the two steps were alternated between. The final output is a volumetric reference image and a motion model that can be used to generate images at any other time point from surrogate measurements.Results: A retrospective patient dataset consisting of eight lung cancer patients was used to evaluate the method. The absolute intensity differences in the lung regions compared to ground truth were 50.8 ± 43.9 HU in peak exhale phases (reference) and 80.8 ± 74.0 in peak inhale phases (generated). The 50th percentile of voxel registration error of all voxels in the lung regions with >5 mm amplitude was 1.3 mm. The MC‐SART was also applied to measured patient cone‐beam projections acquired with a linac‐mounted CBCT system. Results from this patient data demonstrate the feasibility of MC‐SART and showed qualitative image quality improvements compared to other state‐of‐the‐art algorithms.Conclusion: We have developed a simultaneous image reconstruction and motion model estimation method that uses Cone‐beam computed tomography (CBCT) projections and respiratory surrogate measurements to reconstruct a high‐quality reference image and motion model of a patient in treatment position. The method provided superior performance in both HU accuracy and positional accuracy compared to other existing methods. The resultant reference image and motion model can be combined with respiratory surrogate measurements to generate volumetric images representing patient anatomy at arbitrary time points.Keywords
Funding Information
- National Natural Science Foundation of China (81371634, YG2017ZD10,, YG2014ZD05)
- Shanghai Jiao Tong University
This publication has 50 references indexed in Scilit:
- Evaluation of 3D fluoroscopic image generation from a single planar treatment image on patient data with a modified XCAT phantomPhysics in Medicine & Biology, 2013
- Reducing the airflow waveform distortions from breathing style and body position with improved calibration of respiratory effort beltsBioMedical Engineering OnLine, 2013
- Respiratory motion models: A reviewMedical Image Analysis, 2013
- 4D cone beam CT via spatiotemporal tensor frameletMedical Physics, 2012
- Real-time tumor motion estimation using respiratory surrogate via memory-based learningPhysics in Medicine & Biology, 2012
- Inter-fraction variations in respiratory motion modelsPhysics in Medicine & Biology, 2010
- An investigation of 4D cone‐beam CT algorithms for slowly rotating scannersMedical Physics, 2010
- GPU-based fast cone beam CT reconstruction from undersampled and noisy projection data via total variationMedical Physics, 2010
- Clinical application of image-guided radiotherapy, IGRT (on the Varian OBI platform)Cancer/Radiothérapie, 2006
- The distribution of target registration error in rigid-body point-based registrationIEEE Transactions on Medical Imaging, 2001