CT angiography-derived three-dimensional pulmonary vein topography is related to the outcome after cryoballoon ablation
Open Access
- 8 May 2025
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 12, 1496922
Abstract
Background: Following cryoballoon ablation, 20%–30% of the patients show recurrent atrial fibrillation (AF) in long-term follow-up as a consequence of incomplete circumferential ablation lines. Patient selection using computer tomography angiography (CTA)-derived parameters might be feasible to assign patients for cryoballoon ablation according to pulmonary vein (PV) anatomy and topography.Methods: We aimed to analyze the impact of anatomical and topographic PV parameters on the procedural outcome of cryoballoon PVI using a retrospective analysis of 106 patients with paroxysmal AF and preprocedural CTA.Results: Clinical follow-up of the study cohort revealed 78 patients (73.6%, PVI success group) without and 28 patients (26.4%, PVI failure group) with recurrent AF 12 months after cryoablation. Anatomical measurements such as PV diameter, PV area, PV perimeter, or PV eccentricity were not associated with procedural success. The number of occlusion attempts in the right inferior PV was significantly higher in the PVI failure group indicating a technical more complex balloon occlusion. The septum angle α (septum–PV) was significantly lower in the superior PVs of the PVI failure group indicating a direct relation of transseptal puncture site to procedural success. Furthermore, orifice angle β (PV orifice–PV course) was increased and intra-atrial angle γ (septum–PV course) was decreased in the inferior PVs of the PVI failure group.Conclusion: Patient selection using CTA prior to cryoballoon ablation might influence the procedural success of cryoballoon PVI. While PV anatomy in regard to vein size and shape was not associated with procedural outcome, septum, orifice, and intra-atrial angulation were related to procedural success.Keywords
This publication has 23 references indexed in Scilit:
- Safety and efficacy of intracardiac echocardiography–guided zero-fluoroscopic cryoballoon ablation for atrial fibrillation: a prospective randomized controlled trialEP Europace, 2023
- Safety and Effectiveness of a Next-Generation Contact Force CatheterJACC: Clinical Electrophysiology, 2021
- Cryoablation or Drug Therapy for Initial Treatment of Atrial FibrillationNew England Journal of Medicine, 2021
- Cryoballoon Ablation as Initial Therapy for Atrial FibrillationNew England Journal of Medicine, 2021
- Analysis of the anatomical features of pulmonary veins on pre-procedural cardiac CT images resulting in incomplete cryoballoon ablation for atrial fibrillationJournal of Cardiovascular Computed Tomography, 2019
- Pulmonary vein orientation is independently associated with outcomes following cryoballoon-based atrial fibrillation ablationJournal of Cardiovascular Computed Tomography, 2018
- SCCT guidelines for the performance and acquisition of coronary computed tomographic angiography: A report of the Society of Cardiovascular Computed Tomography Guidelines CommitteeJournal of Cardiovascular Computed Tomography, 2016
- Cryoballoon or Radiofrequency Ablation for Paroxysmal Atrial FibrillationNew England Journal of Medicine, 2016
- Association between pulmonary vein orientation and atrial fibrillation-free survival in patients undergoing endoscopic laser balloon ablationEuropean Heart Journal - Cardiovascular Imaging, 2015
- Pulmonary vein ostium shape and orientation as possible predictors of occlusion in patients with drug-refractory paroxysmal atrial fibrillation undergoing cryoballoon ablationEP Europace, 2010