The diagnostic value of metabolic, morphological and heterogeneous parameters of 18F-FDG PET/CT in mediastinal lymph node metastasis of non–small cell lung cancer
Authors:
Open Access
- 15 July 2021
- journal article
- research article
- Published by Wolters Kluwer Health in Nuclear Medicine Communications
- Vol. 42 (11) , 1247-1253
Abstract
Objectives: To investigate the value of PET/CT metabolic, morphological and heterogeneous parameters in the diagnosis of 18F-FDG positive mediastinal lymph node metastasis in non–small cell lung cancer (NSCLC). Patients and methods: A total of 156 patients with pathologically diagnosed NSCLC and underwent 18F-FDG PET/CT scans were enrolled in this study. Mediastinal lymph nodes with 18F-FDG uptake greater than the mediastinum were analyzed. The metabolic parameters of maximum and mean standardized uptake value (SUVmax, SUVmean), SUVratio (node SUVmax/mediastinum SUVmax), metabolic tumor volume (MTV), total lesion glycolysis (TLG), morphological parameters of maximum short diameter (Dmin), CT values and metabolic heterogeneity parameter of coefficient of variation (COV) were measured. The performance of each parameter and their combinations for diagnosis of lymph node metastasis was evaluated through receiver operating characteristic (ROC) curves and binary logistic regression analysis. Results: There were 206 lymph nodes with pathological evidence included in the study, including 103 metastatic and 103 nonmetastatic nodes. The SUVmax, SUVmean, SUVratio, TLG, COV and Dmin of metastatic lymph nodes were significantly higher/greater than those in nonmetastatic ones (P < 0.05). ROC curve analysis revealed that the combination of SUVratio, Dmin and COV showed the highest diagnostic efficacy among all single and combined parameters, the area under the curve (AUC) was 0.907 (P = 0.000), these three parameters all increased the risk of lymph node metastasis, with odds ratios of 1.848, 1.293 and 1.258, respectively (all P < 0.05). Conclusion: Heterogeneity parameter was helpful for the accurate distinction of mediastinal lymph node metastasis in NSCLC. The combination of the SUVratio, Dmin and COV could improve the diagnostic accuracy. Multiple-parameters analysis plays an important complementary role in the diagnosis of lymph node metastasis.Keywords
This publication has 32 references indexed in Scilit:
- Surgery for nonsmall cell lung cancerEuropean Respiratory Review, 2013
- Node/Aorta and Node/Liver SUV Ratios from 18F-FDG PET/CT May Improve the Detection of Occult Mediastinal Lymph Node Metastases in Patients with Non-Small Cell Lung CarcinomaAcademic Radiology, 2012
- Tumour heterogeneity in oesophageal cancer assessed by CT texture analysis: Preliminary evidence of an association with tumour metabolism, stage, and survivalClinical Radiology, 2012
- Intratumor Heterogeneity Characterized by Textural Features on Baseline 18F-FDG PET Images Predicts Response to Concomitant Radiochemotherapy in Esophageal CancerJournal of Nuclear Medicine, 2011
- Impact of Parenchymal Tuberculosis Sequelae on Mediastinal Lymph Node Staging in Patients with Lung CancerJournal of Korean Medical Science, 2011
- Use of the Proposals of the International Association for the Study of Lung Cancer in the Forthcoming Edition of Lung Cancer Staging System to Predict Long-Term Prognosis of Operated PatientsThe Cancer Journal, 2010
- Mediastinal nodal staging of nonsmall cell lung cancer using integrated 18F‐FDG PET/CT in a tuberculosis‐endemic countryCancer, 2007
- Nuclear factor-κB in cancer development and progressionNature, 2006
- Preoperative Staging of Non–Small-Cell Lung Cancer with Positron-Emission TomographyNew England Journal of Medicine, 2000
- Role of cervical mediastinoscopy in staging of non-small cell lung cancer without enlarged mediastinal lymph nodes on CT scanEuropean Journal of Cardio-Thoracic Surgery, 1997