Characterization of streamers in liquid nitrogen under AC voltages using UHF techniques
Authors:
- 16 June 2014
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (3) , 1109-1118
Abstract
Pre-breakdown phenomena in liquid nitrogen (LN2), often referred as streamers, are the precursor of total breakdown due to the more conductive nature of density-change channels compared to the liquid. The paper characterizes streamer behavior in LN2 under AC voltages using ultra high frequency (UHF) and radio frequency current transformer (RFCT) measurements. The aim is to further understand the role of LN2 as insulation as well as the application of non-conventional partial discharge (PD) detection techniques in condition monitoring of future HTS devices. An experiment has been developed to measure PD events in LN2 using narrowband and wideband methods simultaneously. PD detection following IEC 60270 standards allows measurement of the amount of charge transferred at the terminals while the use of a UHF senor with a bandwidth up to 3 GHz can provide better resolution in the time domain. Results from the UHF sensor show that PD in LN2 appears in the form of multiple pulses which are suggested to be due to the expansion and collapse of the gaseous channels. The pulse burst phenomenon was not observed by the narrowband detection. Instead, a slowly damped signal was measured, which may result from the integration of multiple individual events. The experiment also allows correlation of PD measurements with images of pre-breakdown streamers using shadow photography. The characteristics of streamers in LN2 are discussed based on the observation of the density-change channels together with the corresponding discharge signature.Keywords
This publication has 21 references indexed in Scilit:
- Analysis of partial discharge activity by a conducting particle in liquid nitrogen under AC voltages adopting UHF techniqueCryogenics, 2010
- Partial discharge characterization of streamers in liquid nitrogen under applied AC voltagesIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Variable pressure and temperature liquid nitrogen cryostat for optical measurements with applied electric fieldsMeasurement Science and Technology, 2004
- Prebreakdown phenomena at high voltage in liquid nitrogen and comparison with mineral oilIEEE Transactions on Dielectrics and Electrical Insulation, 2002
- A pulsed GTEM system for UHF sensor calibrationIEEE Transactions on Instrumentation and Measurement, 1998
- Prebreakdown Light Emission and Current Pulses in Liquid NitrogenJapanese Journal of Applied Physics, 1998
- Prebreakdown Density Change Streamer in Liquid NitrogenJapanese Journal of Applied Physics, 1997
- The excitation of UHF signals by partial discharges in GISIEEE Transactions on Dielectrics and Electrical Insulation, 1996
- Corona discharges and bubbling in liquid nitrogenJournal of Physics D: Applied Physics, 1975
- Mechanism of Electrical Breakdown in Saturated Hydrocarbon LiquidsJournal of Applied Physics, 1956