In-Vitro Localization of Initial Flow-Induced Thrombus Formation in Bileaflet Mechanical Heart Valves
- 1 January 2009
- journal article
- biomedical engineering
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 55 (1) , 19-23
Abstract
A major concern with mechanical heart valve prostheses is still the need for lifelong anticoagulation to prevent valve thrombosis and thrombembolism. Knowledge of the localization of initial thrombus formation on the prosthesis may help to improve valve design. Since observation of early clot deposition in vivo is difficult, the aim of this study was a detailed assessment of the initial stages of thrombus formation at bileaflet mechanical heart valves by means of an in-vitro clotting model. Four different bileaflet mechanical heart valves (St. Jude Medical, CarboMedics, ATS and On-X) were investigated in a mock circulation in aortic position using enzyme-activated milk resembling blood clotting potential. Initial development of clot formation on the valves was documented photographically and frequency of occurrence was analyzed for both location and valve type. For the bileaflet valves, clot depositions could be found in a distinct pattern similar in all types. In initial stages, clots developed downstream of the leaflets near the orifice ring, 61.5 ± 5.8% of which were hinge associated, but 38.5 ± 5.8% were located isolated laterally and medially remote of the hinge region, providing new information on thrombus formation potentially useful for improvement of valve design.Keywords
This publication has 15 references indexed in Scilit:
- Spatio-temporal Flow Analysis in Bileaflet Heart Valve Hinge Regions: Potential Analysis for Blood Element DamageAnnals of Biomedical Engineering, 2007
- Identification of a 2-stage platelet aggregation process mediating shear-dependent thrombus formationBlood, 2006
- Flow-Induced Platelet Activation in Bileaflet and Monoleaflet Mechanical Heart ValvesAnnals of Biomedical Engineering, 2004
- An in vitro assessment by means of laser Doppler velocimetry of the medtronic advantage bileaflet mechanical heart valve hinge flowThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Microflow fields in the hinge region of the CarboMedics bileaflet mechanical heart valve designThe Journal of Thoracic and Cardiovascular Surgery, 2002
- An In Vitro Study of the Hinge and Near-Field Forward Flow Dynamics of the St. Jude Medical® Regent™ Bileaflet Mechanical Heart ValveAnnals of Biomedical Engineering, 2000
- Velocities, Shear Stresses and Blood Damage Potential of the Leakage Jets of the Medtronic Parallel™ Bileaflet ValveThe International Journal of Artificial Organs, 2000
- Results with mechanical cardiac valvular prosthesesThe Annals of Thoracic Surgery, 1995
- A blood analogue for the experimental study of flow-related thrombosis at prosthetic heart valvesCardiovascular Research, 1983
- Structural aspects of the milk clotting process. Comparative features with the blood clotting processMolecular and Cellular Biochemistry, 1975