Effect of vibration characteristics and vibror arrangement on the tactile perception of the upper arm in healthy subjects and upper limb amputees
Open Access
- 13 November 2019
- journal article
- research article
- Published by Springer Nature in Journal of NeuroEngineering and Rehabilitation
- Vol. 16 (1) , 1-16
Abstract
Background: Vibrotactile stimulation is a promising venue in the field of prosthetics to retrain sensory feedback deficits following amputation. Discrimination is well established at the forearm level but not at the upper arm level. Moreover, the effects of combining vibration characteristics such as duration and intensity has never been investigated. Method: We conducted experiments on spatial discrimination (experiment 1) and tactile intensity perception (experiment 2), using 9 combinations of 3 intensities and 3 durations of vibror stimulations device. Those combinations were tested under 4 arrangements with an array of 6 vibrors. In both experiments, linear orientation aligned with the upper arm longitudinal axis were compared to circular orientation on the upper arm circumference. For both orientations, vibrors were placed either with 3cm space between the center of 2 vibrors or proportionally to the length or the circumference of the subject upper arm. Eleven heathy subjects underwent the 2 experiments and 7 amputees (humeral level) participated in the spatial discrimination task with the best arrangement found. Results: Experiment 1 revealed that circular arrangements elicited better scores than the linear ones. Arrangements with vibrors spaced proportionally elicited better scores (up to 75% correct) than those with 3 cm spacing. Experiment 2, showed that the perceived intensity of the vibration increases with the intensity of the vibrors’ activation, but also with their duration of activation. The 7 patients obtained high scores (up to 91.67% correct) with the circular proportional (CP) arrangement. Discussion: These results highlight that discrete and short vibrations can be well discriminated by healthy subjects and people with an upper limb amputation. These new characteristics of vibrations have great potential for future sensory substitution application in closed-loop prosthetic control.Keywords
This publication has 57 references indexed in Scilit:
- Phantom pain is associated with preserved structure and function in the former hand areaNature Communications, 2013
- Sensory feedback prosthesis reduces phantom limb pain: Proof of a principleNeuroscience Letters, 2012
- The role of feed-forward and feedback processes for closed-loop prosthesis controlJournal of NeuroEngineering and Rehabilitation, 2011
- Phantom limb pain: a case of maladaptive CNS plasticity?Nature Reviews Neuroscience, 2006
- Direct neural sensory feedback and control of a prosthetic armIEEE Transactions on Neural Systems and Rehabilitation Engineering, 2005
- Evaluation of prosthetic usage in upper limb amputeesDisability and Rehabilitation, 2004
- Tactile sensory anisotropy: Weber's contribution.Journal of Experimental Psychology: Human Perception and Performance, 1999
- A tactile stimulation device for measuring two-point and gap discrimination thresholds in humansBehavior Research Methods, Instruments, & Computers, 1990
- Projected and receptive fields: A comparison of projected areas of sensations evoked by intraneural stimulation of mechanoreceptive units, and their innervation territoriesActa Physiologica Scandinavica, 1983
- A KEY TO THE CLASSIFICATION OF CUTANEOUS MECHANORECEPTORSJournal of Investigative Dermatology, 1977