Is Subcutaneous Route an Alternative to Intravenous Route for Mouse Contrast-Enhanced Magnetic Resonance Imaging at 1.5 T?
Open Access
- 13 June 2019
- journal article
- research article
- Published by Hindawi Limited in Concepts in Magnetic Resonance Part A
- Vol. 2019, 1-11
Abstract
The present work compares intravenous (IV) and subcutaneous (SC) routes for contrast-enhanced MRI (CE-MRI) in mice. For that purpose, we selected two contrast media used in clinical practice. MRI acquisitions were performed at 1.5 T on five adult mice (Swiss, 41 g +/- 3 g). On each animal, four acquisitions were achieved with IV and SC administration of either Gd-DOTA or MS-325 (1 acquisition per week). For each route, 0.1 mL of NaCl and 0.1 mL of contrast agent were injected. For each acquisition, 200 T1-weighted images were acquired in a 2 h 34 min time lapse. For each route and contrast medium, dynamic contrast enhancement (DCE) curves were obtained. Time-to-peak (TTP), uptake, and washout constant-time values and contrast-to-noise ratio (CNR) were extracted. IV route TTP value was 4.9 min with Gd-DOTA and 5.4 min with MS-325. SC route TTP was 43.3 min with Gd-DOTA and 45.0 min with MS-325. Despite slower uptake constant-time, we show that SC is a potentially valuable alternative to the IV route in mouse preclinical CE-MRI.Keywords
This publication has 50 references indexed in Scilit:
- A Low Cost Metal-Free Vascular Access Mini-Port for Artifact Free Imaging and Repeated Injections in MicePLOS ONE, 2013
- Practical Dynamic Contrast Enhanced MRI in Small Animal Models of Cancer: Data Acquisition, Data Analysis, and InterpretationPharmaceutics, 2012
- Multifunctional Eu3+/Gd3+ dual-doped calcium phosphate vesicle-like nanospheres for sustained drug release and imagingBiomaterials, 2012
- Evaluation of Mouse Tail-Vein Injections Both Qualitatively and Quantitatively on Small-Animal PET Tail ScansJournal of Nuclear Medicine Technology, 2011
- New Dual Mode Gadolinium Nanoparticle Contrast Agent for Magnetic Resonance ImagingPLOS ONE, 2009
- Manganese-Enhanced MRI: An Exceptional Tool in Translational NeuroimagingSchizophrenia Bulletin, 2007
- The imaging continuum: bench to biomarkers to diagnosticsJournal of Labelled Compounds and Radiopharmaceuticals, 2007
- Preclinical Safety Assessment of Vasovist (Gadofosveset trisodium), a New Magnetic Resonance Imaging Contrast Agent for AngiographyInvestigative Radiology, 2006
- OsiriX: An Open-Source Software for Navigating in Multidimensional DICOM ImagesJournal of Digital Imaging, 2004
- “Keyhole” method for accelerating imaging of contrast agent uptakeJournal of Magnetic Resonance Imaging, 1993