Detecting load failures using the induction motor as a transducer
Authors:
- 1 December 2008
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 196-199
Abstract
This work shows the feasibility of detecting load mechanical failures in drive train by using the induction motor as a transducer and applying MCSA (Motor Current Signature Analysis) technique to identify the characteristic fault frequency components. Furthermore, it presents the detection of problems in the transmission system and its relationship with the problems originated in the attached load. Data extract from industrial fans shows the effectiveness of the methodology.Keywords
This publication has 8 references indexed in Scilit:
- Mechanical Load Fault Detection in Induction Motors by Stator Current Time-Frequency AnalysisIEEE Transactions on Industry Applications, 2006
- Bearing Damage Detection via Wavelet Packet Decomposition of the Stator CurrentIEEE Transactions on Instrumentation and Measurement, 2004
- A simplified technique for detecting mechanical faults using stator current in small induction motors2002
- Quantitative evaluation of induction motor broken bars by means of electrical signature analysisIEEE Transactions on Industry Applications, 2001
- A review of induction motors signature analysis as a medium for faults detectionIEEE Transactions on Industrial Electronics, 2000
- Induction motors' faults detection and localization using stator current advanced signal processing techniquesIEEE Transactions on Power Electronics, 1999
- Motor bearing damage detection using stator current monitoringIEEE Transactions on Industry Applications, 1995
- Effects of time-varying loads on rotor fault detection in induction machinesIEEE Transactions on Industry Applications, 1995