A robust gas sensing strategy decoding polymer degradation for reliable lifetime prediction under near-ambient conditions
Authors:
- Ruiyang DouRDRuiyang Dou
- Jiawei TangJTJiawei Tang
- Wei HuangWHWei Huang
- Bihui JinBJBihui Jin
- Pengjian GongPGPengjian Gong
- Guangxian LiGLGuangxian Li
- Yajie LeiYLYajie Lei
- Xueyan ZhaoXZXueyan Zhao
- Qiang LiuQLQiang Liu
- Hongbing ChenHCHongbing Chen
Preprint
- 30 March 2026
- preprint
- Published by Elsevier in SSRN Electronic Journal
Abstract
The reliable assessment of long-term polymer performance under near-ambient conditions presents a significant challenge. Conventional accelerated testing often induces mechanistic distortions, whereas direct monitoring under mild conditions is limited by exceedingly weak signals. In response to these challenges, the present study develops a robust gas sensing strategy based on infrared spectroscopy, aiming to shift the research paradigm from the prevailing, yet unreliable, approach of accelerated extrapolation to one centered on accurate analysis under near-ambient conditions of aging. Firstly, the fundamental issue of pressure-variable gas quantification in sealed systems was resolved. We uncovered the deterministic relationship between gas molar absorptivity and molar fraction, establishing a dual-variable quantitative model immune to total pressure. This model provides a universal and highly accurate solution for direct analysis, exhibiting relative prediction errors of less than 0.67% for CO2 and 0.70% for CO. Building on this, a modular sensing platform with exceptional environmental compatibility was constructed. Its design, a decoupled architecture that separates environmental simulation from gas analysis, ensures high repeatability with pooled RSDs of 0.25% for CO2 and 0.31% for CO while achieving ultra-low detection limits of 4.6 ppb for CO2 and 336.0 ppb for CO, thereby enabling the reliable capture of trace chemical signals generated during mild aging. Secondly, the universality and transformative potential of the robust gas sensing strategy were validated through its application to diverse polymer systems, including polyimide (PI) membrane, polydimethylsiloxane (PDMS) foam, and polyphenylene oxide (PPO) foams of varying densities. The strategy successfully monitored early-stage gas release under irradiation, mild thermal, and multi-field coupled aging conditions. A full demonstration of its capability was then conducted using PPO foam as a model system. This involved acquiring aging kinetics under near-ambient conditions (25-90 °C), establishing a quantitative chemical damage-mechanical property correlation, and ultimately achieving reliable polymer lifetime prediction with independently verified accuracy exceeding 90%. More significantly, leveraging the strategy’s high-resolution analytical power, a clear cross-scale regulatory mechanism was elucidated for the first time, whereby the macroscopic cellular structure enhances chain mobility. This accelerated mobility promotes oxygen mass transfer, thereby switching the intrinsic aging pathway from random chain scission to complete oxidation. The robust gas sensing strategy created herein not only offers a generalizable new paradigm for lifespan assessment under near-ambient conditions aging but, by revealing the mechanism of physical structure modulation of degradation pathways, also lays a new scientific foundation for controlling material degradation through rational design.Keywords
This publication has 30 references indexed in Scilit:
- Monitoring gas evolution during ageing of industrial supercapacitors studied by in situ GC-MSEnergy Storage Materials, 2026
- Quantitative study of microplastic degradation in urban hydrosystems: Comparing in situ environmentally aged microplastics vs. artificially aged materials generated via accelerated photo-oxidationJournal of Hazardous Materials, 2025
- Unveiling the hidden impact: How biodegradable microplastics influence CO2 and CH4 emissions and Volatile Organic Compounds (VOCs) profiles in soil ecosystemsJournal of Hazardous Materials, 2024
- Detection of volatile organic compounds in adulterated tea using Fourier transform infrared spectroscopy and Proton-transfer-reaction mass spectrometryFood Chemistry, 2023
- Understanding the early-stage release of volatile organic compounds from rapeseed oil during deep-frying of tubers by targeted and omics-inspired approaches using PTR-MS and gas chromatographyFood Research International, 2022
- Thermal degradation and pyrolysis kinetic behaviour of glass fibre-reinforced thermoplastic resin by TG-FTIR, Py-GC/MS, linear and nonlinear isoconversional modelsJournal of Materials Research and Technology, 2021
- Mechanistic insights into toluene degradation under VUV irradiation coupled with photocatalytic oxidationJournal of Hazardous Materials, 2020
- The use of infrared spectroscopic techniques to characterize nanomaterials and nanostructures: A reviewAnalytica Chimica Acta, 2018
- Benefit of the Use of GCxGC/MS Profiles for 1D GC/MS Data Treatment Illustrated by the Analysis of Pyrolysis Products from East Asian Handmade PapersJournal of the American Society for Mass Spectrometry, 2018
- Real-time method for the identification and quantification of hydrocarbon pyrolysis products: Part I. Development and validation of the infra red techniqueJournal of Analytical and Applied Pyrolysis, 2011