The corrosion performance of Cu alloy wire bond on Al pad in molding compounds of various chlorine contents under biased-HAST
Authors:
- 1 May 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05695503,p. 419-424
Abstract
The present article investigated the performance and interfacial behavior between Cu wire bond and Al pad under molding compounds of different chlorine contents. The epoxy molding compounds (EMCs) were categorized as ultra-high chlorine, high chlorine and low chlorine, respectively, with 24, 7.6, and 4.3 ppm chlorine contents. The ball bonds were stressed under 130°C/85%RH with biased voltage of 10V. The interfacial evolution between Cu wire bond and Al pad was investigated in EMC of three chlorine contents after the biased-HAST test. The Cu bonding wires used in the plastic ball grid array (PBGA) package include bare Cu wire (4N Cu) and Pd coated Cu alloy wire (98Cu2Pd). The as bonded wire bond exhibits an average Cu-Al DV1C thickness of ~0.12 um in both types of Cu wire. Two Cu-Al IMC layers, Cu 9 Al 4 and CuAl 2 , analyzed by EDX were formed after 100h of biased-HAST test. The joint failed in 192h and 1296h, respectively, under ultra-high and high chlorine content EMC. The joint lasts longer than 2000h with low chlorine content EMC. The corrosion of IMC formed between Cu wire and Al pad, occurs in the ultra-high and high chlorine molding compound. The results of EDX analysis indicate that the chlorine ion diffuses from molding compound to DVIC through the crack formed between IMC and Al pad. Al 2 O 3 was formed within the DVIC layer. It is believed the existence of Al 2 O 3 accelerates the penetration of the chlorine ion and thus the corrosion.Keywords
This publication has 13 references indexed in Scilit:
- The influence of Pd on the interfacial reactions between the Pd-plated Cu ball bond and Al padSurface and Coatings Technology, 2013
- Effects of reliability testing methods on microstructure and strength at the Cu wire-Al pad interface2013
- Corrosion of the Cu/Al interface in Cu-Wire-bonded integrated circuits2013
- The Pd distribution and Cu flow pattern of the Pd-plated Cu wire bond and their effect on the nanoindentationMaterials Science and Engineering: A, 2012
- Nickel–palladium bond pads for copper wire bondingMicroelectronics Reliability, 2011
- Bond reliability under humid environment for coated copper wire and bare copper wireMicroelectronics Reliability, 2011
- Reliability of palladium coated copper wire2010
- Reliability and failure analysis of fine copper wire bonds encapsulated with commercial epoxy molding compoundMicroelectronics Reliability, 2010
- Cu wire bond microstructure analysis and failure mechanismMicroelectronics Reliability, 2010
- Effects of Cu/Al intermetallic compound (IMC) on copper wire and aluminum pad bondabilityIEEE Transactions on Components and Packaging Technologies, 2003