Extension of high power deuterium operation of negative ion based neutral beam injector in the large helical device
- 1 November 2019
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (11) , 113322
Abstract
Second deuterium operation of the negative ion based neutral beam injector was performed in 2018 in the large helical device. The electron and ion current ratio improves to Ie/Iacc(D) = 0.31 using the short extraction gap distance of 7 mm between the plasma grid (PG) and the extraction grid (EG). The strength of the magnetic field by the electron deflection magnet installed in the EG increases by 17% at the PG ingress surface, which effectively reduces the electron component in the negative ion rich plasma in the vicinity of PG apertures. The reduction of the electron current made it possible to operate at a high power arc discharge and beam extraction. Then, the deuterium negative ion current increases to 55.4 A with the averaged current density of 233 A/m2. The thermal load on the EG using 7 mm gap distance is 0.6 times smaller than the thermal load using a 8 mm gap caused by the reduction of coextracted electron current. The injection beam power increases to 2.9 MW in the beam line BL3, and the total beam injection power increases to 7 MW by three beam lines in the second deuterium campaign.Keywords
This publication has 30 references indexed in Scilit:
- Status of the ITER heating neutral beam systemNuclear Fusion, 2009
- Overview of the RF source development programme at IPP GarchingNuclear Fusion, 2006
- High Power Neutral Beam Injection in LHDPlasma Science and Technology, 2006
- High power beam injection using an improved negative ion source for the large helical deviceReview of Scientific Instruments, 2004
- Engineering prospects of negative-ion-based neutral beam injection system from high power operation for the large helical deviceNuclear Fusion, 2003
- Improvement of a large negative ion source for the Large Helical Device neutral beam injectorReview of Scientific Instruments, 2002
- Compensation of beam deflection due to the magnetic field using beam steering by aperture displacement technique in the multibeamlet negative ion sourceReview of Scientific Instruments, 2001
- Negative hydrogen ion source development for large helical device neutral beam injector (invited)Review of Scientific Instruments, 2000
- Overview of the Large Helical Device projectNuclear Fusion, 1999
- Suppression of accelerated electrons in a high-current large negative ion sourceReview of Scientific Instruments, 1997