Electrochemical sensors based on molecularly imprinted polymers (MIPs) leverage predetermined recognition sites (templates) for binding of analytes of interest, resulting in high selectivity and sensitivity, ease of preparation and portability. The choice of monomers and cross-linkers depends heavily on choice of substrate for in situ electropolymerization, and damage to the template caused by methods used to wash away the analyte after formation of MIP on the substrate result in limitations for batch-compatible synthesis methods of such sensors. In this paper, we describe a method to utilize low-cost ENIG finish PCB electrodes as electrochemical sensor substrates for detection of melamine, a common adulterant in milk, through molecular imprinting in polyaniline (PANI). The MIP was synthesized using chemical synthesis method and drop-casted onto the electrodes, thus realizing a low-cost fabrication method. Preliminary results for melamine detection are reported, along with performance evaluation of various synthesis methods to synthesize polyaniline.Keywords
This publication has 32 references indexed in Scilit:
- Synthesis of water‐soluble conductive copolymer based on polyanilinePolymers for Advanced Technologies, 2015
- Electrochemical Detection of MelamineElectroanalysis, 2014
- Conducting Polyaniline Nanowire and Its Applications in Chemiresistive SensingNanomaterials, 2013
- Voltamperometric Discrimination of Urea and Melamine Adulterated Skimmed Milk PowderSensors, 2012
- A Novel Electrochemical Method for Sensitive Detection of Melamine in Infant Formula and Milk using Ascorbic Acid as Recognition ElementBulletin of the Korean Chemical Society, 2012
- Screening and confirmatory methods for the determination of melamine in cow’s milk and milk-based powdered infant formula: Validation and proficiency-tests of ELISA, HPLC-UV, GC-MS and LC-MS/MSFood Control, 2011
- Preparation and Application of Urea Electrochemical Sensor Based on Chitosan Molecularly Imprinted FilmsElectroanalysis, 2011
- An enzyme linked immunosorbent assay for the determination of cyromazine and melamine residues in animal muscle tissuesFood Control, 2010
- Canine renal failure syndrome in three dogsJournal of Veterinary Science, 2006
- Novel biosensor fabrication methodology based on processable conducting polyaniline nanoparticlesElectrochemistry Communications, 2005