Erosion Tests on Samples from the New Orleans Levees
Authors:
- J. L. BriaudJBJ. L. Briaud
- H. C. ChenHCH. C. Chen
- A. V. GovindasamyAGA. V. Govindasamy
- R. StoresundRSR. Storesund
- 14 October 2007
- conference paper
- Published by American Society of Civil Engineers (ASCE)
- p. 1-16
Abstract
Twenty three samples were retrieved from eleven locations at the top of the levees around New Orleans. Thirteen were samples from Shelby tubes while ten were bag samples. These samples were tested in the EFA ort Erosion Function Apparatus. The results of such an erosion test is an erosion function which links the erosion rate in mm/hr to the water velocity in m/s. The results obtained show a large variation of erosion resistance among the soils tested and point to the need to evaluate the remaining levees. New ideas for such an evaluation and for improving the redundancy of such long linear systems are presented.Keywords
This publication has 4 references indexed in Scilit:
- Erosion Function Apparatus for Scour Rate PredictionsJournal of Geotechnical and Geoenvironmental Engineering, 2001
- SRICOS: Prediction of Scour Rate in Cohesive Soils at Bridge PiersJournal of Geotechnical and Geoenvironmental Engineering, 1999
- Hydrodynamic Forces on a Rough WallReviews of Modern Physics, 1949
- The equilibrium of grains on the bed of a streamProceedings of the Royal Society of London. A. Mathematical and Physical Sciences, 1940