Characterization of applicator material for treatment of superficial lesions in brachytherapy
Open Access
- 11 December 2024
- journal article
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 12 (4A (Suppl.) , e2611
Abstract
The treatment of superficial lesions by brachytherapy is performed using radioactive sources positioned inside tumors or at a short distance from them, to deposit the prescribed dose in the target volume. In the case of treating skin lesions, due to the proximity between the source and the patient's surface, it is important to use applicators that conduct the radiation source to the region to be treated, ensuring the safety and hygiene of the process. The treatment of keloids, for example, can be performed by brachytherapy. Considering that the applicators must undergo rigorous quality control, this study presents an evaluation of an applicator developed for the treatment of skin lesions, consisting of fifteen spheres of synthetic material, for use in High dose rate brachytherapy (HDR) equipment, model Nucletron Digital V3, equipped with an Ir-192 source. It was considered important to determine whether the spheres are suitable for medical use, direct contact with the patient's skin and sterilization methods. Furthermore, it was necessary to consider the material's resistance to the irradiation process, since the spheres must be used in multiple applications. In this sense, it was necessary to define the material of the spheres and, through this characterization, consider their suitability for the proposed use. Since the spheres were acquired with generic specifications, this study aimed to perform analyses to characterize the material, defining its composition. Consequently, the focus was to evaluate their safe use in the brachytherapy applicator.Keywords
This publication has 17 references indexed in Scilit:
- Additive manufacturing of high-performance, flexible 3D siloxane-based scintillators through the sol-gel routeApplied Materials Today, 2024
- Exploring the impact of Bi2O3 particle size on the efficacy of dimethylpolysiloxane for medical gamma/X-rays shielding applicationsRadiation Physics and Chemistry, 2024
- An extensive investigation on gamma shielding properties of dimethylpolysiloxane modified with nano sized SnO2 and CdORadiation Physics and Chemistry, 2024
- Development of a silicone-based radio-fluorogenic dosimeter using dihydrorhodamine 6GPhysica Medica, 2023
- Nano tin oxide/dimethyl polysiloxane reinforced composite as a flexible radiation protecting materialScientific Reports, 2023
- Gamma irradiation-induced degradation of silicone encapsulationMaterials Today Communications, 2022
- Flexible 3D printed silicones for gamma and neutron radiation shieldingRadiation Physics and Chemistry, 2021
- Influence of the addition of organo-montmorillonite nanofiller on cross-linking of polysiloxanes – FTIR studiesSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2021
- Thermal degradation kinetics of functional polysiloxane with pendent γ-chloropropyl groupsPolymer Bulletin, 2020
- Kinetic aspects of the thermal degradation of poly(dimethyl siloxane) and poly(dimethyl diphenyl siloxane)Polymer Degradation and Stability, 2002