Abstract
We propose a least laxity first (LLF) scheduling algorithm for a heterogeneous population of thermostatically controlled loads (TCL), aimed at providing regulation services for the power grid. TCLs periodically switch between on and off states in order to keep their monitored temperature in a certain comfort band. In our scheme, TCLs inform a central controller of their anticipated deadlines to switch states, allowing for their switching events to be scheduled. An LLF policy schedules these transitions to provide regulation with minimum deviation from the autonomous evolution of the TCLs. To manage large populations, we bundle requests with similar laxity values in a limited number of clusters, considerably reducing computational and communication costs, and preserving the privacy of participants.Keywords
This publication has 7 references indexed in Scilit:
- Safe protocols for generating power pulses with heterogeneous populations of thermostatically controlled loadsEnergy Conversion and Management, 2013
- Modeling and control of aggregated air conditioning loads under realistic conditions2013
- Load frequency control by aggregations of thermally stratified electric water heaters2012
- Real-time scheduling of deferrable electric loads2012
- Development and Validation of Aggregated Models for Thermostatic Controlled Loads with Demand Response2012
- A market-based mechanism for providing demand-side regulation service reserves2011
- A class of models for load management application and evaluation revisitedIEEE Transactions on Power Systems, 1992