Changes in particle area measurements due to SEM accelerating voltage and magnification
Authors:
- Silvia Elena BarbosaSBSilvia Elena Barbosa
- 1 July 2003
- journal article
- research article
- Published by Wiley in Microscopy Research and Technique
- Vol. 61 (5) , 463-468
Abstract
Scanning electron microscopy (SEM) images of polymer blends followed by digital image analysis is a rapid and easy method for the measurement of particle size and dispersion. The particle size determination is done with appropriate off‐line image analysis software. However, it is necessary to understand how machine parameters involved in the formation of the SEM image influence area measurements of morphological features. In this work, the influence of the accelerating voltage used during image acquisition was examined with standard samples and with polymer blend samples. A systematic study centered on two mutually exclusive assumptions of area variation or no area variation with accelerating voltage was carried out. The off‐line image analysis software was then calibrated according to the assumptions. The main conclusion of this study was that kV has an important influence on area measurement in SEM images. This effect was observed for different standard materials (metallic and polymeric) and for the range of magnifications used. The higher the accelerating voltages, the greater the error at high magnification for polymer samples. As the beam energy increases, the primary electrons penetrate more deeply into the solid specimen, producing low‐resolution signals. These signals degrade the image and surface details, which became less well defined. Therefore, images of polymer samples must be taken at lower accelerating voltages so the desired surface details can be imaged clearly. To avoid area measurement errors, particle measurement must be done with the calibration of the off‐line image analysis software corresponding to the accelerating voltage and magnification used for the acquired images. Microsc. Res. Tech. 61:463–468, 2003.Keywords
Funding Information
- CONICET (National Research Council of Argentina)
- UNS (National University of the South)
This publication has 7 references indexed in Scilit:
- Rubber-Toughening of Polycarbonate-Nylon Blends1996
- Phase Separation of Two-Phase Epoxy Thermosets That Contain Epoxidized Triglyceride Oils1996
- Polymer Microscopy1996
- Structure and properties of polypropylene-elastomer blends1995
- Scanning Electron Microscopy and X-Ray Microanalysis1992
- Practical Stereology1986