Biomechanical Comparison of Glutaraldehyde-Crosslinked Gelatin Fibrinogen Electrospun Scaffolds to Porcine Coronary Arteries
- 13 November 2015
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 138 (1) , 011001-01100112
Abstract
Cardiovascular disease (CVD) is the leading cause of death for Americans. As coronary artery bypass graft surgery (CABG) remains a mainstay of therapy for CVD and native vein grafts are limited by issues of supply and lifespan, an effective readily available tissue-engineered vascular graft (TEVG) for use in CABG would provide drastic improvements in patient care. Biomechanical mismatch between vascular grafts and native vasculature has been shown to be the major cause of graft failure, and therefore, there is need for compliance-matched biocompatible TEVGs for clinical implantation. The current study investigates the biaxial mechanical characterization of acellular electrospun glutaraldehyde (GLUT) vapor-crosslinked gelatin/fibrinogen cylindrical constructs, using a custom-made microbiaxial optomechanical device (MOD). Constructs crosslinked for 2, 8, and 24 hrs are compared to mechanically characterized porcine left anterior descending coronary (LADC) artery. The mechanical response data were used for constitutive modeling using a modified Fung strain energy equation. The results showed that constructs crosslinked for 2 and 8 hrs exhibited circumferential and axial tangential moduli (ATM) similar to that of the LADC. Furthermore, the 8-hrs experimental group was the only one to compliance-match the LADC, with compliance values of 0.0006±0.00018 mm Hg−1 and 0.00071±0.00027 mm Hg−1, respectively. The results of this study show the feasibility of meeting mechanical specifications expected of native arteries through manipulating GLUT vapor crosslinking time. The comprehensive mechanical characterization of cylindrical biopolymer constructs in this study is an important first step to successfully develop a biopolymer compliance-matched TEVG.Keywords
This publication has 75 references indexed in Scilit:
- Fabrication of small-diameter vascular scaffolds by heparin-bonded P(LLA-CL) composite nanofibers to improve graft patencyInternational Journal of Nanomedicine, 2013
- Crosslinking and composition influence the surface properties, mechanical stiffness and cell reactivity of collagen-based filmsActa Biomaterialia, 2012
- Constitutive Modeling of Mouse Carotid Arteries Using Experimentally Measured Microstructural ParametersBiophysical Journal, 2012
- Lymphatic lipid transport: sewer or subway?Trends in Endocrinology & Metabolism, 2010
- Biaxial biomechanical properties of self-assembly tissue-engineered blood vesselsJournal of The Royal Society Interface, 2010
- A bilayered elastomeric scaffold for tissue engineering of small diameter vascular graftsActa Biomaterialia, 2010
- A small diameter, fibrous vascular conduit generated from a poly(ester urethane)urea and phospholipid polymer blendBiomaterials, 2009
- A Microstructurally Motivated Model of the Mechanical Behavior of Tissue Engineered Blood VesselsAnnals of Biomedical Engineering, 2008
- Development of a tissue-engineered vascular graft combining a biodegradable scaffold, muscle-derived stem cells and a rotational vacuum seeding techniqueBiomaterials, 2008
- Current status of prosthetic bypass grafts: A reviewJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2005