Can CT-based assessment of lateral malleolus anatomy indicate when and how to perform an intramedullary fixation in distal fibula fractures? An analysis of 150 ankles
Authors:
- Vincenzo GiordanoVincenzo Giordano
- Pedro Henrique AzevedoPAPedro Henrique Azevedo
- Caio PeresCPCaio Peres
- Marcelo PerucciMPMarcelo Perucci
- Matheus RodriguesMRMatheus Rodrigues
- Rafael MeirelesRMRafael Meireles
- Robinson Esteves PiresRPRobinson Esteves Pires
- Alexandre Godoy-SantosAlexandre Godoy-Santos
- Peter V. GiannoudisPGPeter V. Giannoudis
- 19 August 2022
- journal article
- research article
- Published by Springer Nature in European Journal of Orthopaedic Surgery & Traumatology
- Vol. 33 (3) , 601-609
Abstract
Purpose The primary aim was to analyse the lateral malleolus morphology with a focus on the shape of the distal fibula for IM fixation of the fibula in infra- and transsyndesmotic fracture patterns. The secondary aim was to propose a treatment algorithm according to the lateral malleolar anatomy. Methods 77 healthy, skeletally mature volunteers underwent CT scanning of the ankle. The fibula medullary canal and its cortical thickness were quantitatively analysed at 4 different levels measured from the fibular tip (1.5 cm, 3.0 cm, 4.5 cm, and 6.0 cm). A geometric classification was proposed, and a decision algorithm was developed. Statistical significance was set at a p-value < 0.05. Results The smallest diameter of the medullary canal of the fibula was at 6.0 cm from the tip of the fibula, in 98.2% of the ankles. The distal fibula can be classified into triangular and rectangular type, according to the cortical thickness index (p < 0.0001). In 16.7% ankles, the internal diameter of the fibula at 6.0 cm was equal or narrower than 3.5 mm (p < 0.05). Conclusion The shape of the distal fibula as evaluated by CT-guided analysis allows for IM osteosynthesis of the lateral malleolus in 83% of individuals. In our study, the smallest diameter of the medullary canal of the fibula was located 6.0 cm from the tip of the lateral malleolus. Coronal CT evaluation is advantageous in indicating which type of IM implant should be used safely for infra- and transsyndesmotic fracture patterns, potentially reducing intraoperative risks.Keywords
This publication has 27 references indexed in Scilit:
- Percutaneous Intramedullary Screw Fixation of Distal Fibula Fractures: A Case Series and Systematic ReviewThe Journal of Foot and Ankle Surgery, 2017
- Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibulaInjury, 2017
- Should syndesmotic screws be removed after surgical fixation of unstable ankle fractures?The Bone & Joint Journal, 2016
- A biomechanical comparison study of a modern fibular nail and distal fibular locking plate in AO/OTA 44C2 ankle fracturesJournal of Orthopaedic Surgery and Research, 2016
- A prospective randomised controlled trial of the fibular nailversusstandard open reduction and internal fixation for fixation of ankle fractures in elderly patientsThe Bone & Joint Journal, 2016
- Anatomical examination of the fibula: Digital imaging study for osseointegrated implant installationJournal of Otolaryngology - Head & Neck Surgery, 2015
- Intramedullary fixation of distal fibular fractures: a systematic review of clinical and functional outcomesJournal of Orthopaedics and Traumatology, 2014
- Minimally invasive percutaneous plate osteosynthesis for ankle fractures: a prospective observational cohort studyEuropean Journal of Orthopaedic Surgery & Traumatology, 2013
- Structural and cellular assessment of bone quality of proximal femurBone, 1993
- The Measurement of Observer Agreement for Categorical DataBiometrics, 1977