THE DECAY OF METASTABLE ATOMS IN A PULSED DISCHARGE IN KRYPTON
Authors:
- D. S. SmithDSD. S. Smith
- R. TurnerRTR. Turner
- 1 December 1963
- journal article
- Published by Canadian Science Publishing in Canadian Journal of Physics
- Vol. 41 (12) , 1949-1959
Abstract
The rate of decay of metastable krypton atoms in the 1s5 state has been measured in the range 0.2 to 1.8 mm Hg of krypton pressure. The measured values of decay time τ can be fitted to a theoretical curve 1/τ = 30/p + 75p + 44p2∙ (p = pressure in mm). The effects of collisions with electrons have been estimated. Comparison with previous measurements of destruction frequencies in neon and argon show that the relative importance of three-body collisions is greater for krypton than for the other two gases.Keywords
This publication has 5 references indexed in Scilit:
- Diffusion, De-excitation, and Three-Body Collision Coefficients for Excited Neon AtomsPhysical Review B, 1959
- Measurement of Time Varying Optical AbsorptionReview of Scientific Instruments, 1955
- Lifetimes of Metastable States of Noble GasesPhysical Review B, 1953
- Electron Removal in Krypton AfterglowsPhysical Review B, 1952
- REVIEW: Resonance Radiation and Excited AtomsThe Astrophysical Journal, 1934