An original method of simulating the articular cartilage in the context of in vitro biomechanical studies investigating the proximal femur
Open Access
- 5 January 2022
- journal article
- research article
- Published by Spandidos Publications in Experimental and Therapeutic Medicine
- Vol. 23 (3) , 1-5
Abstract
Biomechanical testing is a necessity given the development of novel implants used in the osteosynthesis of hip fractures. The purpose of biomechanical testing is to recreate realistic conditions similar to the in vivo conditions. Although biomechanical testing of hip arthroplasty has been standardized since the 1970s, there is no consensus at present on testing methodology for osteosynthesis of hip fractures. Most biomechanical studies examining the fractures of the proximal femur in order to optimize implants opt for loading the bone‑implant ensemble directly on the femoral head or using a metallic loading part. This loading technique fails to perform a mechanical stress distribution similar to in vivo conditions, which could alter the outcome. The present study aimed to design loading/unloading cups with mechanical properties that resemble those of the cartilage at the hip level. Through the impression and scanning of the cast models obtained, a digital 3D model was created in STL format and this was processed in order to obtain the computer numerical control (CNC) trajectories of the printing head. For prototyping using additive manufacturing technology, a thermoplastic polymer with biochemical properties, such as tensile strength, that resemble those of the adult hip and a Stratasys FORTUS 250 mc CNC machine were used. Loading/unloading cups with similar anatomy and biomechanical forces compared with those of the adult hip were created, which allowed the experimental simulation of the conditions during walking.Keywords
This publication has 18 references indexed in Scilit:
- Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fracturesInjury, 2015
- A biomechanical comparison of composite femurs and cadaver femurs used in experiments on operated hip fracturesJournal of Biomechanics, 2014
- Statistical consequences of using bone mineral density to pair cadaver femurs in comparative ex vivo hip fracture studiesBone & Joint Research, 2014
- Is Tip Apex Distance As Important As We Think? A Biomechanical Study Examining Optimal Lag Screw PlacementClinical Orthopaedics and Related Research, 2014
- Side plate fixation vs. intramedullary nailing in an unstable medial femoral neck fracture model: A comparative biomechanical studyClinical Biomechanics, 2011
- Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigationClinical Biomechanics, 2009
- Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluationInjury, 2006
- Three-dimensional dynamic hip contact area and pressure distribution during activities of daily livingJournal of Biomechanics, 2006
- Relationship Among Biomechanical, Biochemical, and Cellular Changes Associated with OsteoarthritisCritical Reviews in Biomedical Engineering, 2001
- Age-related changes in the tensile properties of human articular cartilage: a comparative study between the femoral head of the hip joint and the talus of the ankle jointBiochimica et Biophysica Acta (BBA) - General Subjects, 1991