Total retinal blood flow measurement with ultrahigh speed swept source/Fourier domain OCT
Open Access
- 13 May 2011
- journal article
- research article
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 2 (6) , 1539-1552
Abstract
Doppler OCT provides depth-resolved information on flow in biological tissues. In this article, we demonstrate ultrahigh speed swept source/Fourier domain OCT for visualization and quantitative assessment of retinal blood flow. Using swept laser technology, the system operated in the 1050-nm wavelength range at a high axial scan rate of 200 kHz. The rapid imaging speed not only enables volumetric imaging with high axial scan densities, but also enables measurement of high flow velocities in the central retinal vessels. Deep penetration in the optic nerve and lamina cribrosa was achieved by imaging at 1-µm wavelengths. By analyzing en-face images extracted from 3D Doppler data sets, absolute flow in single vessels as well as total retinal blood flow was measured using a simple and robust protocol that does not require measurement of Doppler angles. The results from measurements in healthy eyes suggest that ultrahigh speed swept source/Fourier domain OCT could be a promising technique for volumetric imaging of retinal vasculature and quantitation of retinal blood flow in a wide range of retinal diseases.Keywords
This publication has 50 references indexed in Scilit:
- Stable absolute flow estimation with Doppler OCT based on virtual circumpapillary scansBiomedical Optics Express, 2010
- High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiographyJournal of Biomedical Optics, 2010
- Quantitative cerebral blood flow with Optical Coherence TomographyOptics Express, 2010
- Visualization of phase retardation of deep posterior eye by polarization-sensitive swept-source optical coherence tomography with 1-µm probeOptics Express, 2009
- Measurement of total blood flow in the normal human retina using Doppler Fourier-domain optical coherence tomographyBritish Journal of Ophthalmology, 2009
- Three-dimensional pointwise comparison of human retinal optical property at 845 and 1060 nm using optical frequency domain imagingJournal of Biomedical Optics, 2009
- In vivo high-contrast imaging of deep posterior eye by 1-μm swept source optical coherence tomography and scattering optical coherence angiographyOptics Express, 2007
- Autocalibration of spectral-domain optical coherence tomography spectrometers for in vivo quantitative retinal nerve fiber layer birefringence determinationJournal of Biomedical Optics, 2007
- Optical coherence angiographyOptics Express, 2006
- Measurement of intraocular distances by backscattering spectral interferometryOptics Communications, 1995