Primary failure of cardiac resynchronization therapy: what are the causes and is it worth considering a second attempt? A single-centre experience
Authors:
Open Access
- 15 August 2008
- journal article
- research article
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 10 (11) , 1308-1312
Abstract
Cardiac resynchronization therapy (CRT) has been validated as an effective treatment for patients with drug-refractory congestive heart failure and left bundle branch block. Failure of implantation of the left ventricular (LV) lead has been reported in 10–15% of patients. The goal of our study was to determine the causes of failure and the success rate following a repeat procedure by the same operators. We reviewed our last 100 consecutive cases of CRT before July 2007. The procedure was considered as unsuccessful if it had to be interrupted before the placement of the LV lead in an appropriate position, because of patient’s haemodynamic status or if the procedure duration exceeded 3 h. Cardiac resynchronization therapy was unsuccessful in 10 patients (5 men, mean age: 72 ± 11 years). The causes of failure of CRT were as follows: no target vein other than the great cardiac vein ( n = 5), coronary sinus dissection ( n = 1), and a lateral vein too small to provide a stable location for the LV lead ( n = 4). A second procedure was attempted in four patients and was successful in all cases. In our study results, failure of CRT was observed in 10% of the patients. A second procedure can be attempted in a selected group of patients and is associated with a high success rate.Keywords
This publication has 12 references indexed in Scilit:
- Guidelines for cardiac pacing and cardiac resynchronization therapy: The Task Force for Cardiac Pacing and Cardiac Resynchronization Therapy of the European Society of Cardiology. Developed in Collaboration with the European Heart Rhythm AssociationEuropean Heart Journal, 2007
- Implantation of cardiac resynchronization therapy systems in the CARE-HF trial: procedural success rate and safetyEP Europace, 2007
- The Effect of Cardiac Resynchronization on Morbidity and Mortality in Heart FailureNew England Journal of Medicine, 2005
- Cardiac Resynchronization in Chronic Heart FailureNew England Journal of Medicine, 2002
- Prophylactic Implantation of a Defibrillator in Patients with Myocardial Infarction and Reduced Ejection FractionNew England Journal of Medicine, 2002
- Doppler myocardial imaging to evaluate the effectiveness of pacing sites in patients receiving biventricular pacingJACC, 2002
- Effects of Multisite Biventricular Pacing in Patients with Heart Failure and Intraventricular Conduction DelayNew England Journal of Medicine, 2001
- Angiographic Anatomy of the Coronary Sinus and Its TributariesPacing and Clinical Electrophysiology, 1998
- A Method for Permanent Transvenous Left Ventricular PacingPacing and Clinical Electrophysiology, 1998
- Permanent Left Ventricular Pacing With Transvenous Leads Inserted Into The Coronary VeinsPacing and Clinical Electrophysiology, 1998