Membrane patches as ion channel probes for scanning ion conductance microscopy
- 16 September 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Faraday Discussions
- Vol. 193, 81-97
Abstract
We describe dual-barrel ion channel probes (ICPs), which consist of an open barrel and a barrel with a membrane patch directly excised from a donor cell. When incorporated with scanning ion conductance microscopy (SICM), the open barrel (SICM barrel) serves to measure the distance-dependent ion current for non-invasive imaging and positioning of the probe in the same fashion of traditional SICM. The second barrel with the membrane patch supports ion channels of interest and was used to investigate ion channel activities. To demonstrate robust probe control with the dual-barrel ICP-SICM probe and verify that the two barrels are independently addressable, current–distance characteristics (approach curves) were obtained with the SICM barrel and simultaneous, current–time (I–T) traces were recorded with the ICP barrel. To study the influence that the distance between ligand-gated ion channels (i.e., large conductance Ca2+-activated K+ channels/BK channels) and the ligand source (i.e., Ca2+ source) has on channel activations, ion channel activities were recorded at two fixed probe–substrate distances (Dps) with the ICP barrel. The two fixed positions were determined from approach curves acquired with the SICM barrel. One position was defined as the “In-control” position, where the probe was in close proximity to the ligand source; the second position was defined as the “Far” position, where the probe was retracted far away from the ligand source. Our results confirm that channel activities increased dramatically with respect to both open channel probability and single channel current when the probe was near the ligand source, as opposed to when the probe was far away from the ligand source.Keywords
Funding Information
- National Science Foundation (1507341)
This publication has 35 references indexed in Scilit:
- Rectification of Nanopores at SurfacesJournal of the American Chemical Society, 2011
- Intrinsic Kinetics of Gypsum and Calcium Sulfate Anhydrite Dissolution: Surface Selective Studies under Hydrodynamic Control and the Effect of AdditivesThe Journal of Physical Chemistry C, 2011
- Simultaneous Noncontact Topography and Electrochemical Imaging by SECM/SICM Featuring Ion Current Feedback RegulationJournal of the American Chemical Society, 2010
- Integrated Ultramicroelectrode−Nanopipet Probe for Concurrent Scanning Electrochemical Microscopy and Scanning Ion Conductance MicroscopyAnalytical Chemistry, 2010
- Tarantula Huwentoxin-IV Inhibits Neuronal Sodium Channels by Binding to Receptor Site 4 and Trapping the Domain II Voltage Sensor in the Closed ConfigurationJournal of Biological Chemistry, 2008
- The ultrastructure of patch-clamped membranes: a study using high voltage electron microscopy.Journal of Cell Biology, 1991
- Patch cramming: Monitoring intracellular messengers in intact cells with membrane patches containing detector inn channelsNeuron, 1990
- Calcium-activated potassium channelsTrends in Neurosciences, 1987
- Patch Clamp Techniques for Studying Ionic Channels in Excitable MembranesAnnual Review of Physiology, 1984
- Ca-dependent K channels with large unitary conductance in chromaffin cell membranesNature, 1981