Two-year Outcomes of Computed Tomography-based and Computed Tomography Free Navigation for Total Knee Arthroplasties
Authors:
- Arno MartinAMArno Martin
- A von StrempelASA von Strempel
- 1 August 2006
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 449, 275-282
Abstract
Optimal component position in all planes and well-balanced soft tissues facilitate a good clinical outcome and long-term survival after total knee arthroplasties. We investigated the accuracy of implantation of navigated total knee arthroplasties at 3 months followup and the influence on the clinical outcome at 2 years followup. Forty-four patients (44 procedures) were enrolled in our prospective study. One half of the surgeries were performed using a computed tomography-based navigation system, and half were performed with imageless navigation. Outcomes were based on the Insall knee score parameters, anterior knee pain, patient satisfaction, feeling of instability, and step test. The radiographic parameters were the mechanical axis, tibial slope, lateral distal femoral angle, and medial proximal tibial angle. The radiographic measurements were similar in both groups (patients within +/- 3 degrees inaccuracy range in computed tomography-based/imageless groups; mechanical axis 86%/81%, tibial slope 95%/91%, lateral distal femoral angle 95%/91%, medial proximal tibial angle 91%/95%). The imageless system provided equal radiographic results, but we found improved ligament balancing in the computed tomography free group. The computed tomography-based approach has a good pre-operative planning procedure, but is more expensive and time consuming. Therapeutic Study, Level II. See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 31 references indexed in Scilit:
- Navigation Improves Accuracy of Rotational Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2004
- Computer-assisted total knee replacementThe Journal of Bone and Joint Surgery. British volume, 2004
- Alignment in total knee arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2004
- Computer-assisted knee arthroplasty versus a conventional jig-based techniqueThe Journal of Bone and Joint Surgery. British volume, 2004
- Low reproducibility of the intra–operative measurement of the transepicondylar axis during total knee replacementActa Orthopaedica, 2004
- Navigation in der Knieendoprothetik - vorläufige klinische Erfahrungen und prospektiv vergleichende Studie gegenüber konventioneller lmplantationstechnikZeitschrift für Orthopädie und ihre Grenzgebiete, 2001
- The Swedish Knee Arthroplasty Register 1975-1997: An update with special emphasis on 41,223 knees operated on in 1988-1997Acta Orthopaedica, 2001
- Radiographic assessment of knee alignment after total knee arthroplastyThe Journal of Arthroplasty, 1988
- Total condylar knee arthroplasty: Prosthetic component positioning and radiolucent linesActa Orthopaedica, 1984
- Alignment in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 1983