Navigators for motion detection during real-time MRI-guided radiotherapy
Authors:
- Mette K StamMSMette K Stam
- Sjoerd P M CrijnsSCSjoerd P M Crijns
- Bernard A ZonnenbergBZBernard A Zonnenberg
- Maurits M BarendrechtMBMaurits M Barendrecht
- Marco van VulpenMVMarco van Vulpen
- Jan J W LagendijkJLJan J W Lagendijk
- Bas W RaaymakersBRBas W Raaymakers
- 3 October 2012
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 57 (21) , 6797-6805
Abstract
An MRI-linac system provides direct MRI feedback and with that the possibility of adapting radiation treatments to the actual tumour position. This paper addresses the use of fast 1D MRI, pencil-beam navigators, for this feedback. The accuracy of using navigators was determined on a moving phantom. The possibility of organ tracking and breath-hold monitoring based on navigator guidance was shown for the kidney. Navigators are accurate within 0.5 mm and the analysis has a minimal time lag smaller than 30 ms as shown for the phantom measurements. The correlation of 2D kidney images and navigators shows the possibility of complete organ tracking. Furthermore the breath-hold monitoring of the kidney is accurate within 1.5 mm, allowing gated radiotherapy based on navigator feedback. Navigators are a fast and precise method for monitoring and real-time tracking of anatomical landmarks. As such, they provide direct MRI feedback on anatomical changes for more precise radiation delivery.Keywords
This publication has 25 references indexed in Scilit:
- Towards inherently distortion-free MR images for image-guided radiotherapy on an MRI acceleratorPhysics in Medicine & Biology, 2012
- Towards MRI-guided linear accelerator control: gating on an MRI acceleratorPhysics in Medicine & Biology, 2011
- Real-time correction of magnetic field inhomogeneity-induced image distortions for MRI-guided conventional and proton radiotherapyPhysics in Medicine & Biology, 2010
- Treatment plan adaptation for MRI-guided radiotherapy using solely MRI data: a CT-based simulation studyPhysics in Medicine & Biology, 2010
- Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CTInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2010
- First Demonstration of Combined kV/MV Image-Guided Real-Time Dynamic Multileaf-Collimator Target TrackingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2009
- A phantom evaluation of a stereo‐vision surface imaging system for radiotherapy patient setupMedical Physics, 2005
- Motion adaptive x-ray therapy: a feasibility studyPhysics in Medicine & Biology, 2000
- Adaptive motion compensation in MRI: Accuracy of motion measurementMagnetic Resonance in Medicine, 1991
- Adaptive technique for high-definition MR imaging of moving structures.Radiology, 1989